← All AAI Flashcard Decks

Code Compliance & Standards Flashcards

7 cards from real AAI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Code Compliance & Standards flashcards as text
  1. A contractor wants to swap the specified adhesive for a cheaper product. What is generally required?

    Answer: Engineer of record approval of a product with equivalent qualified performance

    Substitutions need the design professional's approval, supported by evaluation data such as an ESR that shows equivalent performance.

  2. What does an ICC-ES Evaluation Service Report (ESR) provide for an adhesive anchor system?

    Answer: Code-compliance evidence with design values and installation parameters

    An ESR shows the product meets code requirements and lists its bond strengths, conditions of use, and installation details.

  3. Under ACI 318, what is the allowable effective embedment depth range for adhesive anchors, in terms of anchor diameter da?

    Answer: 4da to 20da

    ACI 318 limits adhesive anchor embedment to between 4da and 20da.

  4. For post-installed anchors that are not torqued, what minimum edge distance does ACI 318 require when product-specific test data is not available?

    Answer: 6da

    ACI 318 requires a minimum edge distance of 6da for untorqued post-installed anchors unless product-specific tests justify less.

  5. Under ACI 318, what is the critical edge distance cac for adhesive anchors when product test data is not available?

    Answer: 2hef

    ACI 318 sets cac for adhesive anchors at 2hef.

  6. Which IBC chapter sets the special inspection requirements that apply to post-installed anchors?

    Answer: Chapter 17

    IBC Chapter 17 covers special inspections and tests, including post-installed anchors in concrete.

  7. Which concrete condition must ACI 355.4 qualification account for when adhesive anchors will be used in tension zones?

    Answer: Cracked concrete

    Anchors used where concrete may crack must be qualified for cracked concrete under ACI 355.4.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy