Read the first 7 Blueprint Reading & Technical Drawings flashcards as text
  1. On an anchor detail, the abbreviation "hef" refers to which dimension?

    Answer: Effective embedment depth

    hef is the effective embedment depth used in ACI 318 anchor design and must be achieved in the field.

  2. A drawing note reads "(4) 5/8" DIA. THREADED RODS @ 8" O.C." What does "O.C." mean?

    Answer: On center

    O.C. means on center, the spacing measured from the centerline of one anchor to the centerline of the next.

  3. An anchor plan dimension is given to a column grid line. What is the correct reference point for laying out the anchor?

    Answer: The grid line referenced in the dimension string

    Layout must start from the reference the designer dimensioned, usually a grid line, so tolerances don't accumulate.

  4. A section cut symbol on a plan shows "3/S-501" in its bubble. Where do you find that section?

    Answer: Section 3 on sheet S-501

    In standard callouts the top number identifies the section or detail and the bottom number identifies the sheet it is drawn on.

  5. The drawings call for a 4-1/2" embedment, but the slab is only 5" thick and the installer's hole would come close to breaking through the back. What should the installer do?

    Answer: Stop and notify the engineer or supervisor before drilling

    Any conflict between drawings and field conditions must go to the engineer of record; installers may not change design parameters.

  6. On a structural drawing, a dimension marked "NTS" means:

    Answer: Not to scale

    NTS means the drawing is not to scale, so only the written dimensions may be used, never scaled measurements.

  7. Where would an installer most likely find the required adhesive product and its ICC-ES evaluation report number?

    Answer: The structural general notes or specifications

    Adhesive anchor products, approved alternates, and ESR numbers are typically listed in the structural general notes or project specifications.

Written and edited by , founder of Practice Test Geeks, with AI assistance. Exam facts are checked against the official sources linked below. Editorial policy

Sources & references

Exam facts on this page (fees, format, dates, passing scores) are checked against these official sources; the date is our last check. Editorial policy

  1. concrete.org — Fees, retake fee, test delivery, exam format, passing score, renewal, time limit, score validity, score release, eligibility · verified Nov 2026