The 30 highest-yield WALMART MAINTENANCE facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
60 questions
60 min time limit
70% to pass
- A compactor machine fails to cycle after pressing the start button. The first thing to verify is: → Safety door or gate interlock is fully closed
- What is the primary safety concern when working near energized electrical bus bars in a retail facility's electrical room? → Arc flash and electrical shock hazard
- What does 'GPF' stand for in the context of Walmart restroom fixtures, and why is it important? → Gallons Per Flush — it determines water usage efficiency of toilets and urinals
- What is the maximum height a maintenance worker should work from without fall protection? → 6 feet in general industry
- What is the maximum voltage drop allowed by NEC recommendations for branch circuits in commercial buildings? → 3%
- A maintenance technician is about to work on a 480V electrical panel. Which minimum PPE is required? → Arc flash suit, face shield, and insulated gloves rated for the voltage
- A circuit breaker keeps tripping repeatedly. What should you investigate? → Investigate the circuit for overloads, short circuits, or ground faults
- Which of the following is an example of a reportable OSHA recordable incident? → A sprained wrist requiring prescription medication
- Which type of defrost system uses hot refrigerant gas from the compressor discharge to melt evaporator frost? → Hot gas defrost
- In a store's electrical panel, what does a 'double-pole' breaker control? → A single 240V circuit
- What is the correct sequence for applying joint compound when finishing a drywall seam in a Walmart retail area? → Tape coat → finish coat → topping coat
- How often should a grease trap in a commercial kitchen be cleaned? → When it reaches 25% capacity or at least monthly, per local codes
- During operation, a riding floor buffer produces excessive vibration. The most probable cause is: → Unbalanced or damaged buffing pad
- A pallet jack's forks will not raise even though the pump handle moves freely. What is the most likely cause? → Low hydraulic fluid level
- When checking a motor's insulation resistance with a megohmmeter, what reading generally indicates acceptable insulation? → At least 1 megohm
- A dock leveler plate does not hold its raised position and slowly sinks when weight is applied. The likely cause is: → Hydraulic cylinder seal leak or faulty hold valve
- Which condition would cause a thermal overload relay to trip a motor circuit? → Motor drawing excessive current due to mechanical overload
- Which pipe material is most commonly used for Walmart store drain, waste, and vent (DWV) systems installed in recent construction? → PVC (polyvinyl chloride)
- What color wire indicates a ground conductor in US electrical systems? → Green or bare copper
- What color is the grounding conductor in standard US electrical wiring? → Green or bare copper
- What is the correct action when a preventive maintenance task reveals a minor oil leak on a piece of equipment? → Tag the equipment out of service and report to the supervisor
- What is the purpose of a ground fault circuit interrupter (GFCI) outlet? → Detect small current leaks to ground and cut power within milliseconds
- Which type of valve is best suited for fully open or fully closed applications in a Walmart plumbing system? → Gate valve
- A PM checklist item calls for 'inspecting belt tension' on a conveyor. What symptom indicates the belt is too loose? → Belt slips or squeals under load
- When installing a hollow-wall anchor (toggle bolt) in drywall to hang a moderate load, which step must be completed FIRST? → Drill a hole slightly larger than the toggle bolt body
- What is the correct procedure when shutting off water to a Walmart restroom for repairs during store hours? → Post an 'Out of Service' sign and notify store management before shutting off water
- What is the minimum hot water temperature required at handwashing stations per health code? → 100°F
- A photoelectric sensor on an automatic door fails to trigger. The FIRST diagnostic step should be: → Check the power supply voltage to the sensor
- A maintenance tech notices a wooden door frame has swollen and the door no longer closes properly. What is the most likely cause? → Moisture absorption causing wood expansion
- Under OSHA's fall protection standard, at what height above a lower level must maintenance workers use fall protection in general industry? → 4 feet