  1. What are the common causes of fire in Singapore commercial buildings?

    Answer: Electrical faults, overloaded circuits, smoking in prohibited areas, cooking mishaps, improper storage of flammable materials, and discarded cigarette butts

    The most common causes include electrical overloading, short circuits, improper use of electrical equipment, careless smoking, unattended cooking, and storage of flammable materials near heat sources.

  2. What is the purpose of fire doors and what must security officers ensure about them?

    Answer: Fire doors resist fire spread for a rated period; security officers must ensure they close automatically, are never propped open, and their seals are intact

    Fire doors are rated to resist fire for 30-120 minutes, containing fire to one area. They must be self-closing (never propped open), have intact smoke seals, and be unobstructed on both sides.

  3. What is a 'fire warden' and can a security officer serve as one?

    Answer: A person trained to lead floor evacuation during fire emergencies; security officers often serve as fire wardens for their assigned areas

    Fire wardens are trained to lead evacuation on their assigned floor, check rooms, assist disabled persons, and report to the control point. Security officers frequently serve as fire wardens.

  4. What is the minimum number of fire drills required per year in Singapore?

    Answer: At least two fire drills per year as required under the Fire Safety Act

    The Fire Safety Act requires at least two fire drills per year (every 6 months) for most commercial and residential buildings in Singapore. Security officers play key roles in organising and conducting drills.

  5. How should a security officer respond to a fire alarm activation?

    Answer: Check the fire alarm panel for the zone, investigate the zone for fire or smoke, call 995 if fire is confirmed, initiate evacuation, and guide occupants to assembly points

    Every alarm must be investigated immediately. Check the panel zone, physically inspect the area. If fire/smoke is found, call 995, activate full evacuation. If false alarm, reset after confirming with the FSM.

  6. What should security officers know about sprinkler systems in Singapore buildings?

    Answer: Individual sprinkler heads activate only when heat reaches their activation temperature; each head operates independently; never obstruct sprinkler heads

    A common misconception is that all sprinklers activate together. In reality, each head activates independently when heated to its rated temperature (typically 68°C). Security must ensure nothing obstructs the sprinkler heads.