  1. When must a radiation protection technician perform a pre-job briefing before radiological work?

    Answer: Before all work covered by a Radiological Work Permit

    Pre-job briefings are required before all RWP-controlled work to ensure all workers understand radiological hazards, controls, dose limits, and emergency procedures.

  2. An 'extremely high radiation area' (EHRA) under 10 CFR 20 requires what additional physical control beyond standard HRA requirements?

    Answer: Physical controls (not just administrative controls) that prevent inadvertent entry

    EHRAs require physical controls such as locked doors or gates that prevent inadvertent or unauthorized entry, beyond mere posting and administrative barriers.

  3. Which instrument is most appropriate for detecting and measuring low-energy beta contamination such as C-14 or H-3?

    Answer: Liquid scintillation counter for H-3; thin-window GM for C-14

    H-3 emits very low-energy betas that require liquid scintillation counting, while C-14's betas require a thin-window GM detector because standard detectors cannot detect their low energies.

  4. What is the purpose of posting a 'Radioactive Material' area sign per 10 CFR 20?

    Answer: To warn individuals that quantities of radioactive material exceeding certain thresholds are present

    Radioactive Material area postings warn personnel that quantities of radioactive material above regulatory thresholds specified in 10 CFR 20 Appendix C are present.

  5. A worker's thyroid bioassay reveals an uptake of I-131 that results in a committed dose equivalent of 15 rem. Under 10 CFR 20, what is the occupational limit for thyroid dose?

    Answer: 50 rem per year

    The occupational dose limit for the thyroid under 10 CFR 20.1201(a)(2) is 50 rem (0.5 Sv) committed dose equivalent per year.

  6. During radiological work planning, what is the primary benefit of performing a mockup or dry run of a task?

    Answer: To identify procedural inefficiencies and reduce actual time—and therefore dose—in the radiation field

    Mockups allow workers to practice a task and optimize their technique before entering the radiation field, directly reducing the time spent in the field and thus the total dose received.

  7. What action should a radiation protection technician take if a survey instrument reads unexpectedly high when entering a posted radiation area?

    Answer: Back out immediately, re-survey the area boundary, and investigate the discrepancy

    An unexpectedly high reading may indicate a changed radiological condition; the technician should exit, re-evaluate the boundary, and investigate before allowing work to proceed.