← All NHIE Flashcard Decks

Exterior Evaluation Flashcards

7 cards from real NHIE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Exterior Evaluation flashcards as text
  1. An inspector observes stair stringers on an exterior deck that are notched to accept the treads. What is the primary concern with this installation?

    Answer: Notching reduces the effective depth of the stringer and may weaken it structurally

    Deep notches in stair stringers reduce the net section depth, significantly weakening the member and creating a potential structural failure point.

  2. Which type of flashing is MOST critical at the intersection of a roof plane and a vertical wall, such as a dormer sidewall?

    Answer: Step flashing integrated with each course of shingles

    Step flashing, installed one piece per shingle course, sheds water at each step rather than relying on a single seal that can fail.

  3. A home inspector finds that downspouts discharge water directly against the foundation wall. What is the BEST practice the inspector should recommend?

    Answer: Extend downspouts at least 6 feet from the foundation or connect to underground drainage

    Extending downspouts at least 6 feet away from the foundation prevents concentrated water from saturating the soil and infiltrating the basement or crawl space.

  4. When inspecting fiber cement siding, which installation deficiency is MOST commonly observed and reported by home inspectors?

    Answer: Insufficient clearance between the siding bottom edge and roof or flashing surfaces

    Fiber cement siding requires a minimum clearance from roofs and flashing to prevent chronic moisture absorption at the cut edges.

  5. What is the purpose of weep holes in a brick veneer wall assembly?

    Answer: To allow moisture that enters the cavity behind the veneer to drain out

    Weep holes at the base of brick veneer allow water that penetrates behind the veneer to drain out rather than accumulate in the cavity.

  6. During an exterior inspection, an inspector notes that the driveway slopes toward the garage rather than away from it. What is the PRIMARY concern?

    Answer: Water will drain toward the garage and may enter the structure during heavy rain

    A driveway sloping toward the garage directs surface water to the garage entry, increasing the risk of water intrusion into the garage or adjacent living space.

  7. Which handrail deficiency on exterior steps should a home inspector flag as a SAFETY concern?

    Answer: A handrail that is not graspable — such as a 2x4 laid flat on top of balusters

    Handrails must be graspable in cross section; a flat 2x4 cannot be properly gripped and fails to provide the support needed to prevent falls.