NERC Cheat Sheet 2026

The 30 highest-yield NERC facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.

  1. Under FAC-003, what must a Transmission Owner do if planned vegetation work cannot be completed as scheduled? Document the reason and reschedule the work as soon as practicable
  2. NERC PRC-023 governs which aspect of relay protection? Transmission relay loadability to prevent incorrect operations under emergency loading
  3. Under NERC PRC-005, what is the maximum allowable maintenance interval for a microprocessor-based relay with communication-assisted trip capability? 6 years
  4. How many NERC Regional Entities operate in North America? Eight
  5. NERC CIP-013 addresses which of the following risks? Supply chain risk management for industrial control systems
  6. What does MTBF stand for in the context of reliability standards? Mean Time Between Failures
  7. NERC CIP-009 requires responsible entities to maintain which type of plans? Recovery plans for BES Cyber Systems
  8. Which of the following is NOT typically included in reliability standards? Time to market
  9. What is the typical duration of a NERC compliance audit cycle for most registered entities? Every 6 years
  10. What is the required timeframe for a Transmission Operator to notify its Reliability Coordinator of an emergency condition under NERC IRO standards? As soon as possible
  11. Under NERC TOP-002, Transmission Operators must assess their systems against which planning events during the operating horizon? P0 through P7 planning events as defined in TPL-001
  12. What is the primary goal of operations management? Maximizing efficiency and resource utilization
  13. CIP-014 was created in response to what type of threat to the bulk electric system? Physical attacks on critical transmission substations
  14. Which NERC functional model registration category applies to entities that own and maintain transmission facilities? Transmission Owner (TO)
  15. Under the NERC registration process, which entity type is responsible for the reliable operation of the interconnected bulk electric system in real time? Reliability Coordinator
  16. Which CIP standard requires responsible entities to have a physical security plan for high and medium impact BES Cyber Systems? CIP-006
  17. What is a 'Find, Fix, Track and Report' (FFT) process in NERC compliance? A streamlined method for handling less serious, self-reported violations
  18. Which NERC CIP standard specifically addresses personnel and training requirements? CIP-004
  19. Which resource is considered non-renewable? Coal
  20. Under NERC PRC-004, what must entities do when a protection system misoperation is identified? Analyze the misoperation, identify the cause, and implement corrective actions
  21. What is the purpose of a Mitigation Plan in NERC compliance? To document how a violating entity will correct a violation and prevent recurrence
  22. What must a responsible entity do within 35 days under CIP-008 after a reportable Cyber Security Incident? Submit an after-action review report
  23. What is a key consideration when integrating renewable energy sources into transmission planning? Intermittency of renewable energy sources
  24. Which of the following is a mandatory element of a Transmission Owner's vegetation management program under FAC-003? An annual vegetation work plan identifying areas and methods
  25. What does NERC standard FAC-001 require of transmission owners? Establishment and documentation of facility ratings methodology
  26. Which NERC standard requires generator owners to verify that generator protection systems coordinate with system protection? PRC-024
  27. Which impact level classification under NERC CIP carries the most stringent security requirements? High impact
  28. Under NERC standards, what is the significance of the 'N-1 contingency' in protection system design? The system must tolerate loss of any single transmission element
  29. What is the general voltage threshold above which NERC FAC-003 typically applies to transmission lines? 200 kV and above
  30. What is the nominal frequency of the Eastern, Western, and Texas (ERCOT) Interconnections in North America? 60 Hz