Branch Circuit Requirements Flashcards
7 cards from real NEC practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Branch Circuit Requirements flashcards as text
GFCI protection is required for 125-volt, 15- and 20-ampere receptacles installed in which dwelling location?
Answer: Garages
NEC 210.8(A) requires GFCI protection for receptacles in garages.
Arc-fault circuit-interrupter (AFCI) protection is required for 120-volt branch circuits supplying outlets in which area?
Answer: Dwelling-unit bedrooms
NEC 210.12(A) requires AFCI protection for branch circuits serving dwelling bedrooms among other rooms.
At what receptacle spacing must outlets be installed along the wall line of a dwelling habitable room?
Answer: No point more than 6 ft from a receptacle
NEC 210.52(A) requires that no point along the wall be more than 6 feet from a receptacle.
Countertop receptacles in a dwelling kitchen must be installed so no point along the counter wall is more than what distance from a receptacle?
Answer: 24 inches
NEC 210.52(C)(1) requires no point more than 24 inches from a countertop receptacle.
A wall counter space 12 inches or wider in a kitchen requires at least how many receptacle outlets?
Answer: One
NEC 210.52(C)(1) requires a receptacle for each counter space 12 inches or wider.
GFCI protection is required for receptacles serving dwelling countertop surfaces in which room?
Answer: Kitchen
NEC 210.8(A)(6) requires GFCI protection for kitchen countertop receptacles.
Outdoor receptacle outlets at a dwelling, both front and back, must be installed at what maximum height above grade?
Answer: 6.5 feet
NEC 210.52(E) requires outdoor receptacles to be not more than 6.5 feet above grade.