Solar Energy System Design & Installation Flashcards
7 cards from real NABCEP practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Solar Energy System Design & Installation flashcards as text
What is the primary purpose of a combiner box in a large PV array?
Answer: To combine multiple string outputs into a single feed to the inverter
A combiner box aggregates the outputs of multiple PV strings into a single DC feed, simplifying wiring runs to the inverter.
Which NEC article primarily governs the installation of solar photovoltaic systems?
Answer: Article 690
NEC Article 690 covers solar photovoltaic systems, including wiring methods, overcurrent protection, and disconnecting means.
A PV system produces 8 kWp DC. If the inverter has a CEC efficiency of 96%, what is the approximate AC output at peak?
Answer: 7.68 kW
Multiplying 8 kWp by 0.96 efficiency yields 7.68 kW AC output at peak conditions.
What is the minimum required ground clearance for conductors on a residential rooftop PV system under NEC requirements?
Answer: The NEC does not specify rooftop conductor ground clearance
The NEC addresses clearances for service drops and overhead conductors, but does not specify a minimum ground clearance for conductors already on a rooftop.
Which factor most directly reduces the output of crystalline silicon PV modules on a hot summer day compared to STC ratings?
Answer: Elevated cell temperature reducing Voc and Pmax
Crystalline silicon has a negative temperature coefficient for power; as cell temperature rises above 25°C, both Voc and Pmax decrease.
In a grid-tied PV system, what is the function of anti-islanding protection?
Answer: Preventing the inverter from back-feeding power during a utility outage
Anti-islanding protection causes the inverter to shut down when utility power is lost, preventing hazardous energization of a de-energized grid.
When sizing DC conductors for a PV source circuit, NEC 690.8 requires the conductor ampacity to be at least what percentage of the module's rated Isc?
Answer: 156%
NEC 690.8 requires DC source-circuit conductors to be rated at 156% of the module's Isc (125% × 125% for continuous current under sunlight).