ASNT Industrial Radiography Radiation Safety Personnel (IRRSP) Exam — Questions and Answers
Question 1: What should be done if the controlled area’s boundaries cannot be properly established during radiographic operations?
- Use warning signs and barriers to clearly mark the area (Correct answer)
- Reduce the use of protective equipment
- Proceed with the operation regardless
- Ignore boundary establishment
Correct answer: Use warning signs and barriers to clearly mark the area
If controlled area boundaries cannot be properly established, it is crucial to clearly mark the perimeter with warning signs and physical barriers. This ensures that unauthorized personnel are aware of the radiation hazard and are prevented from entering the area. This measure helps maintain safety and prevent accidental exposure when ideal conditions are not met.
Question 2: Which combination best describes the integrated approach to radiation protection?
- Shielding only, no need to consider time or distance
- Relying solely on personal protective equipment (PPE)
- Using time, distance, and shielding together (Correct answer)
- Time management, ignoring distance, no shielding
Correct answer: Using time, distance, and shielding together
The integrated approach to radiation protection, often referred to as the "Time, Distance, Shielding" triad, is the most effective strategy. Each of these principles independently reduces radiation exposure, but when applied concurrently, they provide comprehensive protection. This combined method ensures that exposure is minimized through multiple layers of safety.
Question 3: What is the primary purpose of exposure monitoring in industrial radiography?
- To reduce the need for personal protective equipment (PPE)
- To increase productivity
- To ignore safety protocols
- To ensure radiation doses remain within safe limits (Correct answer)
Correct answer: To ensure radiation doses remain within safe limits
Exposure monitoring in industrial radiography is essential for verifying that radiation doses received by workers do not exceed regulatory limits. It involves the use of personal dosimeters and survey meters to track radiation levels and individual exposures. This practice is critical for protecting worker health and complying with radiation safety regulations.
Question 4: An ion-chamber pocket dosimeter must be checked for correct response to radiation at specified intervals. What is the maximum allowable interval for this check, and what is the acceptable accuracy range?
- Every 6 months, within ±25% of the true exposure.
- Every 6 months, within ±10% of the true exposure.
- Every 12 months, within ±30% of the true exposure.
- Every 12 months, within ±20% of the true exposure. (Correct answer)
Correct answer: Every 12 months, within ±20% of the true exposure.
10 CFR 34.47(c) requires that pocket dosimeters or electronic personal dosimeters be checked for correct response to radiation at periods not to exceed 12 months. The regulation also states that acceptable dosimeters must read within plus or minus 20 percent of the true radiation exposure.
Question 5: During an emergency source retrieval operation, which of the following is the most critical element for minimizing the dose received by the response team?
- Developing a specific, detailed plan and rehearsing it before approaching the source. (Correct answer)
- Ensuring the retrieval is performed by the most senior radiographer on site.
- Wearing two sets of personnel dosimeters to ensure an accurate dose reading.
- Having the RSO personally handle the source with long-handled tongs.
Correct answer: Developing a specific, detailed plan and rehearsing it before approaching the source.
The ALARA principle (As Low As Reasonably Achievable) is best served by meticulous planning and practice. A well-rehearsed plan minimizes the time spent in the high radiation area, optimizes distance, and ensures proper use of shielding and tools, thereby reducing the overall exposure to the team more effectively than any other single measure.
Question 6: During radiographic operations, how can the risk of accidental radiation exposure be minimized?
- By increasing the time spent near the source
- By using remote-controlled equipment and proper shielding (Correct answer)
- By not using any protective equipment
- reducing the distance from the radiation source
Correct answer: By using remote-controlled equipment and proper shielding
Minimizing accidental radiation exposure during radiographic operations relies heavily on engineering controls and protective measures. Remote-controlled equipment allows operators to maintain a safe distance from the source, while proper shielding reduces radiation levels in occupied areas. These combined strategies significantly decrease the risk of unintended exposure to personnel.
Question 7: According to 10 CFR 34, if a radiographer's direct-reading pocket dosimeter is found to be off-scale and radiation exposure cannot be ruled out, which of the following actions is required within 24 hours?
- The individual must be immediately removed from all radiation duties for 30 days.
- The individual's personnel dosimeter (e.g., TLD or OSL) must be sent for processing and evaluation. (Correct answer)
- The radiographer must complete a written report to be filed with the NRC.
- A full recalibration of all survey meters on site must be initiated.
Correct answer: The individual's personnel dosimeter (e.g., TLD or OSL) must be sent for processing and evaluation.
10 CFR 34.47(d) specifies that if a direct-reading dosimeter is off-scale (or an electronic personal dosimeter reads over 200 mrem) and exposure is possible, the individual's legal personnel dosimeter that requires processing must be sent for evaluation within 24 hours to determine the actual dose received. The individual is also restricted from work with licensed material until a dose determination is made by the RSO.
Question 8: Within what timeframe must a licensee notify the NRC of a lost or stolen sealed source by telephone?
- Within 24 hours
- Within 30 days
- Within 4 hours (Correct answer)
- Within 72 hours
Correct answer: Within 4 hours
10 CFR 34.91 requires immediate telephone notification to the NRC within 4 hours of discovering a missing, lost, or stolen source.
Question 9: What is the half-life of Iridium-192 (Ir-192), the most commonly used industrial radiography isotope?
- 8.02 days
- 5.27 years
- 30.2 years
- 73.83 days (Correct answer)
Correct answer: 73.83 days
Ir-192 has a half-life of approximately 73.83 days, requiring frequent source replacement but allowing relatively rapid decay for waste management purposes.
Question 10: During a radiographic operation, a radiographer's alarming ratemeter goes off unexpectedly, and the survey meter confirms that the source is not secured in its shielded position. What is the radiographer's most critical immediate responsibility?
- Notify the Radiation Safety Officer (RSO) immediately.
- Disassemble the guide tube to identify the problem.
- Secure the restricted area boundary and prevent unauthorized entry. (Correct answer)
- Immediately attempt to retract the source using the crank.
Correct answer: Secure the restricted area boundary and prevent unauthorized entry.
In an emergency where a source is unshielded, the first and most critical responsibility is to protect people from exposure. This involves securing the restricted area to prevent anyone from entering and being exposed to the unshielded source. Notifying the RSO is also crucial, but securing the area comes first.
Question 11: Which isotope is most commonly used in portable industrial radiography exposure devices due to its appropriate half-life and gamma energy?
- Cobalt-60 (Co-60)
- Iridium-192 (Ir-192) (Correct answer)
- Selenium-75 (Se-75)
- Cesium-137 (Cs-137)
Correct answer: Iridium-192 (Ir-192)
Ir-192 is the most widely used isotope in portable industrial radiography because its ~74-day half-life and average gamma energy (~0.38 MeV) are well-suited for field radiography of steel.
Question 12: How often must sealed sources used in industrial radiography be leak tested under 10 CFR 34?
- Monthly
- Annually
- Every 6 months (Correct answer)
- Every 3 months
Correct answer: Every 6 months
10 CFR 34.27 requires that sealed sources be leak tested at intervals not to exceed 6 months.
Question 13: What written plan is required under 10 CFR 37 for licensees possessing Category 1 or 2 quantities of radioactive material?
- An emergency response plan filed with local fire departments
- A transportation security plan reviewed by the Department of Homeland Security
- A radiation monitoring plan approved by state health authorities
- A physical protection plan addressing security measures and access control (Correct answer)
Correct answer: A physical protection plan addressing security measures and access control
10 CFR 37 requires licensees with Category 1 or 2 quantities of radioactive material to establish and maintain a written physical protection plan covering security measures, access control, and response to security events.
Question 14: What is the primary purpose of the physical protection requirements in 10 CFR 37 for Category 1 and 2 radioactive materials?
- To track cumulative occupational dose to radiation workers
- To prevent unauthorized access, loss, or theft of radioactive materials (Correct answer)
- To ensure proper environmental monitoring near storage areas
- To document emergency contact information for first responders
Correct answer: To prevent unauthorized access, loss, or theft of radioactive materials
10 CFR 37 establishes physical protection requirements to prevent unauthorized access and theft of Category 1 and 2 radioactive materials.
Question 15: A radiographer's film badge is due for exchange. According to 10 CFR 34, what is the maximum replacement frequency for a film badge?
- Weekly
- Monthly (Correct answer)
- Quarterly
- Bi-weekly
Correct answer: Monthly
As per 10 CFR 34.47(a)(3), film badges must be replaced at least monthly. Other types of personnel dosimeters that require replacement, such as TLDs or OSLs, must be replaced at least quarterly.
Question 16: Which of the following instruments is designed to measure an individual's accumulated radiation dose over a period of time, rather than the instantaneous dose rate?
- Geiger-Mueller (GM) Survey Meter
- Audible Alarming Ratemeter
- Thermoluminescent Dosimeter (TLD) (Correct answer)
- Ion Chamber Survey Meter
Correct answer: Thermoluminescent Dosimeter (TLD)
A Thermoluminescent Dosimeter (TLD) or film badge is a type of personal dosimeter that measures the total accumulated radiation dose received by an individual over a specific period (e.g., a month or a quarter). Survey meters and alarming ratemeters measure the current radiation rate (e.g., mR/hr).
Question 17: In a gamma radiography setup, what is the primary purpose of using a collimator?
- To connect the source guide tube to the exposure device.
- To filter out alpha and beta radiation from the beam.
- To narrow the primary radiation beam to the area of interest, reducing scatter and dose. (Correct answer)
- To increase the activity of the radioactive source.
Correct answer: To narrow the primary radiation beam to the area of interest, reducing scatter and dose.
A collimator is a shielding device that shapes and directs the primary radiation beam. Its use reduces the size of the high-radiation area, minimizes scatter radiation, and helps reduce the radiation dose to both the public and radiographic personnel, in line with ALARA principles.
Question 18: An industrial radiographer measures an intensity of 200 mR/hr at a distance of 3 feet from a sealed source. If the radiographer moves to a distance of 12 feet from the source, what will the new radiation intensity be?
- 100 mR/hr
- 12.5 mR/hr (Correct answer)
- 50 mR/hr
- 25 mR/hr
Correct answer: 12.5 mR/hr
The Inverse Square Law states that radiation intensity is inversely proportional to the square of the distance from the source (I₁d₁² = I₂d₂²). The distance increased by a factor of 4 (12 feet / 3 feet). Therefore, the intensity will decrease by the square of this factor (4² = 16). The new intensity is 200 mR/hr divided by 16, which equals 12.5 mR/hr.
Question 19: Which of the following is a primary advantage of an Optically Stimulated Luminescence (OSL) dosimeter compared to a Thermoluminescent Dosimeter (TLD)?
- OSL dosimeters are significantly less expensive to manufacture.
- OSL dosimeters do not require an accredited NVLAP processor for evaluation.
- OSL dosimeters provide an immediate, real-time audible alarm at a preset dose rate.
- OSL dosimeters can be re-read to confirm a dose reading, while TLD readings are destructive. (Correct answer)
Correct answer: OSL dosimeters can be re-read to confirm a dose reading, while TLD readings are destructive.
A key feature of OSL technology is that the reading process, which uses a laser or LED light, is non-destructive. This allows the dosimeter to be re-analyzed multiple times to verify an exposure reading. In contrast, the process of reading a TLD involves heating the crystal, which erases the stored information, making a re-read impossible.
Question 20: During radiographic operations, each radiographer and radiographer's assistant must wear several pieces of monitoring equipment. Which of the following combinations is required by 10 CFR 34.47?
- A personnel dosimeter, a survey meter, and a direct reading dosimeter.
- A direct reading dosimeter, a Geiger-Mueller counter, and an OSL dosimeter.
- A survey meter, an alarming ratemeter, and a film badge.
- An operating alarm ratemeter, a personnel dosimeter, and a direct reading dosimeter. (Correct answer)
Correct answer: An operating alarm ratemeter, a personnel dosimeter, and a direct reading dosimeter.
10 CFR 34.47(a) explicitly states that each individual acting as a radiographer or assistant must wear, on the trunk of the body, a direct reading dosimeter, an operating alarm ratemeter, and a personnel dosimeter (the legal dose of record, such as a TLD or OSL). A survey meter is required for surveys but is not part of the required wearable personnel monitoring equipment.
Question 21: A radiographer's transport vehicle is involved in a traffic accident. After confirming no medical emergencies exist, what is the radiographer's first and most critical radiological safety action?
- Perform a thorough radiation survey of the exposure device and the immediate area to verify shielding integrity. (Correct answer)
- Immediately notify the company's Radiation Safety Officer (RSO).
- Remove the exposure device from the vehicle and place it at least 50 feet away from the accident scene.
- Exchange insurance information with the other driver and then survey the equipment.
Correct answer: Perform a thorough radiation survey of the exposure device and the immediate area to verify shielding integrity.
The immediate priority in any incident involving a radiographic device is to assess the radiological conditions. A survey must be performed to confirm that the source is still properly shielded and that there is no radiation hazard to the public, emergency responders, or the radiographer before any other non-life-saving actions are taken.
Question 22: What is the role of personal dosimeters in radiation protection?
- Measuring the distance from the radiation source
- Reducing the amount of radiation emitted
- Monitoring cumulative radiation exposure (Correct answer)
- Shielding the body from radiation
Correct answer: Monitoring cumulative radiation exposure
Personal dosimeters are essential devices worn by individuals working with radiation. Their primary role is to measure and record the total amount of radiation dose an individual receives over a period. This monitoring helps ensure that workers' cumulative exposure remains within safe regulatory limits and allows for accurate tracking of individual doses.
Question 23: Which of the following pieces of information is NOT required on the shipping paper for a Class 7 (Radioactive) material shipment?
- The date of the last source exchange. (Correct answer)
- The activity of the material in Becquerels (Bq) or Curies (Ci).
- The category of label applied to the package (e.g., YELLOW-II).
- The name of the radionuclide (e.g., Iridium-192).
Correct answer: The date of the last source exchange.
According to 49 CFR 172.203(d), shipping papers for radioactive materials must include the proper shipping name, UN number, radionuclide, activity, category of label, and Transport Index. The date of the last source exchange is a licensee record but is not a required entry on the transportation shipping document.
Question 24: What information must be recorded and reported to the NRC when a licensee transfers a sealed source to another party?
- Only the source serial number and activity level
- The source identity, estimated activity, transfer date, and recipient's license number (Correct answer)
- No reporting is required for routine source transfers between licensed parties
- Only the recipient's name and mailing address
Correct answer: The source identity, estimated activity, transfer date, and recipient's license number
10 CFR 34.31 requires documentation of source transfers including the source identity, estimated activity, transfer date, and the recipient's NRC or Agreement State license number.
Question 25: Where must exposure devices containing sealed sources be stored when not in use?
- In any locked room at the facility
- In a locked vehicle at the job site overnight
- At the device manufacturer's facility between jobs
- In a licensed, secured storage location meeting NRC physical security requirements (Correct answer)
Correct answer: In a licensed, secured storage location meeting NRC physical security requirements
Sealed sources must be stored in NRC-licensed locations that meet physical security requirements under 10 CFR 34 and 10 CFR 37.
Question 26: A radiographer is cranking out a source and feels significant, unusual resistance in the drive cable. Forcing the crank is unsuccessful. What is the most appropriate immediate action?
- Immediately run to the exposure head to see what is blocking the source.
- Continue to apply steady, forceful pressure to crank the source out.
- Attempt to retract the source, and if it retracts, investigate the guide tube for blockages. (Correct answer)
- Disconnect the drive cable from the exposure device to relieve pressure.
Correct answer: Attempt to retract the source, and if it retracts, investigate the guide tube for blockages.
Unusual resistance often indicates a kinked or crushed guide tube. Forcing the crank can cause a source disconnect. The correct procedure is to stop, attempt to safely retract the source, and then investigate the cause of the problem, such as an issue with the guide tube, before proceeding.
Question 27: What level of removable contamination indicates that a sealed source is leaking under NRC regulations?
- 370 Bq (0.010 µCi)
- 1,000 Bq (0.027 µCi)
- 100 Bq (0.003 µCi)
- 185 Bq (0.005 µCi) (Correct answer)
Correct answer: 185 Bq (0.005 µCi)
10 CFR 34.27 defines a leaking source as one with removable contamination exceeding 185 Bq (0.005 µCi).
Question 28: According to 10 CFR Part 34, which of the following is a required daily operability check that must be performed on a radiographic exposure device before its first use of the day?
- A leak test of the sealed source.
- A visual check of the drive cable for kinks and fraying. (Correct answer)
- Verification of the source's activity using a calibration certificate.
- Disassembly and lubrication of the crank mechanism.
Correct answer: A visual check of the drive cable for kinks and fraying.
10 CFR 34.31 requires licensees to perform visual and operability checks on radiographic exposure devices and associated equipment before use each day. This includes inspecting the crank, drive cable, and guide tube connections for any damage or defects that could compromise safety.
Question 29: Which of the following is NOT required on a source inventory record under 10 CFR 34?
- Name of the radiographer who used the source most recently (Correct answer)
- Serial number of the sealed source
- Estimated activity on a specified reference date
- Identity of the isotope
Correct answer: Name of the radiographer who used the source most recently
Source inventory records must identify the isotope, serial number, and estimated activity, but do not specifically require the name of each radiographer who has used the source.
Question 30: What is the ALARA principle in radiation safety?
- As Low As Reasonably Achievable (Correct answer)
- As Long As Radiation Exists
- Always Leave Area Rapidly
- As Large As Radiation Allows
Correct answer: As Low As Reasonably Achievable
ALARA stands for "As Low As Reasonably Achievable" and is a core principle in radiation safety. It mandates that all radiation exposures should be kept to the lowest practical level, even if they are below regulatory limits. This principle guides practices to minimize doses to workers and the public by employing practical and cost-effective measures.
Question 31: An industrial radiographer receives a high dose of radiation over a very short period due to an equipment malfunction. The immediate effects they might experience, such as nausea, are classified as what type of effects?
- Chronic effects
- Genetic effects
- Acute effects (Correct answer)
- Teratogenic effects
Correct answer: Acute effects
Acute effects are health effects that appear within hours, days, or weeks following a high dose of radiation delivered over a short time. Chronic effects result from exposure to smaller doses over a long period. Genetic effects are passed on to future generations, and teratogenic effects are those that affect an embryo or fetus.
Question 32: How often should personal dosimeters be checked for accurate exposure readings?
- Only when radiation levels are suspected to be high
- Every month
- Before and after each work shift (Correct answer)
- Once a year
Correct answer: Before and after each work shift
For accurate and timely monitoring of radiation exposure, personal dosimeters should be checked before and after each work shift. This practice ensures that any exposure received during the shift is recorded and allows for immediate identification of potential overexposures. Regular checks are vital for maintaining an up-to-date record of an individual's cumulative dose.
Question 33: According to 10 CFR Part 34, which of the following is a required daily check for a survey meter before it is used for radiographic operations?
- An operability check using a check source or other appropriate means. (Correct answer)
- Measurement of the half-value layer for the primary isotope being used.
- A leak test of the detector's gas-filled chamber.
- A full multi-point calibration check against a certified source.
Correct answer: An operability check using a check source or other appropriate means.
10 CFR 34.31(a) requires that visual and operability checks be performed on survey meters before use on each day the equipment is to be used. This operability check must be performed using a check source or another appropriate method to ensure the instrument is functioning correctly. Full calibration is required at specific intervals (e.g., every 6 months), not daily.
Question 34: Which of the following is required when a source change is performed on an industrial radiography exposure device?
- The source change must be documented and the new source inventoried (Correct answer)
- The source change must occur only at a licensed fixed facility
- The NRC must be notified before the source change
- Only the manufacturer may perform source changes
Correct answer: The source change must be documented and the new source inventoried
Source changes must be fully documented and the new source added to inventory records to maintain accountability as required under 10 CFR 34.
Question 35: Which device is commonly used to monitor individual radiation exposure in industrial radiography?
- Voltmeter
- Thermometer
- Pressure gauge
- Personal dosimeter (Correct answer)
Correct answer: Personal dosimeter
A personal dosimeter is the specific device designed to monitor individual radiation exposure. These small, wearable devices measure the cumulative radiation dose received by the wearer over a period. They are crucial for tracking occupational exposure and ensuring compliance with radiation safety limits.
Question 36: In the event of a radiographic source being lost or stolen, what immediate action should be taken?
- Immediately report the incident to the RSO and relevant authorities (Correct answer)
- Replace the source with another one
- Conduct a search alone
- Ignore the situation and continue working
Correct answer: Immediately report the incident to the RSO and relevant authorities
The loss or theft of a radiographic source is a severe security and safety breach, as it could lead to uncontrolled radiation exposure. Immediate reporting to the Radiation Safety Officer (RSO) is paramount for internal response, and reporting to relevant authorities (e.g., police, regulatory bodies) is required to initiate a search and prevent public harm. This swift action is critical for public safety and regulatory compliance.
Question 37: Under which of the following conditions is a vehicle required to be placarded with 'RADIOACTIVE' signs on all four sides?
- Anytime a Type A package is transported.
- When the vehicle is carrying a package with a RADIOACTIVE YELLOW-III label. (Correct answer)
- When the vehicle is carrying a package with a RADIOACTIVE WHITE-I label.
- If the total activity in the vehicle exceeds 10 Curies.
Correct answer: When the vehicle is carrying a package with a RADIOACTIVE YELLOW-III label.
According to 49 CFR 172.504, placarding of the transport vehicle is required for any shipment that includes a package bearing a RADIOACTIVE YELLOW-III label. Placarding is not required for packages with only WHITE-I or YELLOW-II labels.
Question 38: During a survey of the restricted area boundary, a radiographer's survey meter needle begins to move erratically, jumping inconsistently. The radiographer is holding the meter steady. Which of the following is a likely cause for this issue?
- The source is not properly collimated, causing a scattered beam.
- The battery is low, but still providing some power.
- The meter's range is set too low for the radiation field.
- There is a loose connection or a short in the cable between the probe and the meter. (Correct answer)
Correct answer: There is a loose connection or a short in the cable between the probe and the meter.
An erratically jumping needle on a survey meter, when held steady, often indicates an electrical problem. A common cause is a faulty or loose cable connecting the detector probe to the meter, which can cause intermittent electrical shorts or open circuits, leading to unstable readings. While a low battery can cause issues, it typically results in a sluggish response or a reading below the 'BAT TEST' line, not erratic jumping.
Question 39: Which of the following is considered a primary characteristic of a stochastic effect of radiation exposure?
- The probability of the effect occurring increases with dose. (Correct answer)
- The effect is typically observed within hours or days of exposure.
- A dose threshold must be exceeded for the effect to occur.
- The severity of the effect increases with the dose received.
Correct answer: The probability of the effect occurring increases with dose.
Stochastic effects are probabilistic, meaning their likelihood of occurring increases with the radiation dose, but the severity is not dependent on the dose. Cancer is the primary example. In contrast, deterministic effects have a dose threshold and their severity increases with the dose (e.g., skin reddening).
Question 40: A radiographer begins a shift and recharges their ion-chamber pocket dosimeter. At the end of the shift, they record the reading. How long must the licensee maintain the records of these daily direct-reading dosimeter readings?
- For 3 years (Correct answer)
- For 1 year
- Until the commission terminates the license
- For 5 years
Correct answer: For 3 years
According to 10 CFR 34.83(a), records of direct reading dosimeter readings required by § 34.47(b) must be maintained by the licensee for 3 years after the record is made. Records of the legal personnel dosimeter results, however, must be kept until the commission terminates the license.
Question 41: A radiographer performs the required survey after an exposure and the survey meter reads zero across the entire length of the guide tube and all around the exposure device. What is the most probable cause and the correct immediate action?
- The survey meter is malfunctioning or saturated; the radiographer should retreat to a safe distance and troubleshoot the issue. (Correct answer)
- A temporary electrical interference is causing a false reading; shaking the meter will likely fix it.
- The source is safely retracted and the survey confirms it; proceed with the next shot.
- The exposure device is exceptionally well-shielded; a zero reading is expected and normal.
Correct answer: The survey meter is malfunctioning or saturated; the radiographer should retreat to a safe distance and troubleshoot the issue.
A properly functioning survey meter will always indicate some level of radiation, even if it's just background, and will show a measurable reading on the surface of a shielded exposure device. A reading of absolute zero is a strong indicator of instrument malfunction (e.g., dead battery, saturation in a very high field) or that the meter is turned off. The safest and most appropriate immediate action is to assume a high radiation field exists and retreat to a safe distance before taking any other action.
Question 42: An industrial radiography exposure device, containing a high-activity sealed source, is considered what type of shipping package?
- Type A Package
- Excepted Package
- Industrial Package
- Type B Package (Correct answer)
Correct answer: Type B Package
Industrial radiography sources typically contain activities that exceed Type A quantity limits. Therefore, they must be transported in a Type B package. A Type B package is designed and tested to withstand severe accident conditions without a significant loss of shielding or containment, as required by regulations like 10 CFR Part 71 and 49 CFR 173.
Question 43: A radiographer has just completed the final exposure of the day at a temporary job site. According to regulations, what specific survey must be performed and documented before securing the exposure device for transport?
- A survey of the exposure device and guide tube to confirm the source is in the fully shielded position. (Correct answer)
- A survey of the entire restricted area to ensure no residual radiation remains.
- A survey of the radiographer's hands and feet for contamination.
- A survey of the transport vehicle to establish a background radiation level.
Correct answer: A survey of the exposure device and guide tube to confirm the source is in the fully shielded position.
10 CFR 34.49(b) explicitly requires that after each exposure, a survey of the radiographic exposure device and the guide tube must be conducted to determine that the sealed source has returned to its shielded position before dismantling equipment. This confirmatory survey is a critical safety step before handling the device or preparing it for transport.
Question 44: A radiographic exposure device is dropped and sustains visible damage to the housing, but a survey confirms the source remains safely shielded. What is the correct course of action?
- Remove the device from service immediately for inspection and recertification by the manufacturer or other authorized person. (Correct answer)
- Wrap the damaged area with high-strength tape and continue work, but report the damage at the end of the shift.
- Perform several test exposures in an un-occupied area to ensure the crank mechanism still works properly.
- Note the damage in the daily log and schedule a maintenance check for the next quarterly inspection.
Correct answer: Remove the device from service immediately for inspection and recertification by the manufacturer or other authorized person.
Any damage to a radiographic exposure device, especially to its housing, could compromise its structural integrity and safety features. Regulations and safe operating practices require that the device be immediately removed from service and not used until it has been inspected, repaired if necessary, and approved for return to service by a qualified entity, such as the manufacturer.
Question 45: Under 10 CFR 37, what access control measure is required for locations where Category 1 or 2 quantities of radioactive material are stored?
- A minimum of two armed security officers must guard the storage area at all times
- A radiation survey must be posted outside the storage area
- Storage areas must be located at least 500 feet from any occupied building
- Access must be limited to individuals with unescorted access authorization (Correct answer)
Correct answer: Access must be limited to individuals with unescorted access authorization
10 CFR 37 requires that access to storage areas containing Category 1 or 2 radioactive materials be limited to individuals who have been granted unescorted access authorization.
Question 46: What type of transport package is required for moving industrial radiography sources between job sites under DOT regulations?
- A DOT Type B package regardless of source activity
- A DOT Type A package meeting activity limits (Correct answer)
- A standard locked metal toolbox with a survey meter attached
- Any container with posted radiation warning labels
Correct answer: A DOT Type A package meeting activity limits
Sealed sources used in portable industrial radiography are transported in DOT-approved Type A packages, provided the activity does not exceed Type A quantity limits.
Question 47: Which isotope used in industrial radiography has the longest half-life among those listed below?
- Cobalt-60 (Co-60) — 5.27 years (Correct answer)
- Thulium-170 (Tm-170) — 128.6 days
- Iridium-192 (Ir-192) — 73.83 days
- Selenium-75 (Se-75) — 119.78 days
Correct answer: Cobalt-60 (Co-60) — 5.27 years
Co-60 has a half-life of approximately 5.27 years, making it the longest-lived of the common industrial radiography isotopes and requiring less frequent source replacement.
Question 48: Which of the following pieces of information is NOT typically required on a radiation survey record?
- The model and serial number of the survey instrument used.
- The name of the individual who performed the survey.
- The date and location of the survey.
- The manufacturer of the film used for the exposures. (Correct answer)
Correct answer: The manufacturer of the film used for the exposures.
A radiation survey record must contain essential information to be a useful and compliant document. This includes the date, location, identification of the instrument used (model/serial number), the results of the survey, and the name of the person performing it. The type or manufacturer of the film being used for the radiographic exposures is irrelevant to the radiation survey itself and is not a required component of the survey record.
Question 49: According to the Law of Bergonié and Tribondeau, which of the following cells would be MOST radiosensitive?
- Developed bone cells
- Adult muscle tissue
- Rapidly dividing, undifferentiated cells (Correct answer)
- Mature nerve cells
Correct answer: Rapidly dividing, undifferentiated cells
The Law of Bergonié and Tribondeau states that radiosensitivity is directly proportional to the rate of cell division (mitotic activity) and inversely proportional to the degree of cell differentiation. Therefore, cells that are rapidly dividing and are not specialized (undifferentiated), such as stem cells in bone marrow or the gastrointestinal lining, are the most sensitive to radiation.
Question 50: A worker is exposed to a significant whole-body dose of radiation. After an initial period of nausea and fatigue, they feel relatively well for several days. This symptom-free period is known as the:
- Manifest illness stage
- Prodromal stage
- Recovery stage
- Latent stage (Correct answer)
Correct answer: Latent stage
Acute Radiation Syndrome (ARS) typically progresses through four stages. The initial symptoms occur in the prodromal stage. This is followed by the latent stage, a period where the individual appears and feels healthy, which can last for hours or weeks. The manifest illness stage is when severe symptoms return, and the final stage is either recovery or death.
Question 51: How can time be managed to minimize radiation exposure during industrial radiography?
- Ignoring the time factor and focusing on distance
- Prolonging the exposure duration
- Increasing the time spent in the radiation area
- Reducing the time spent near the radiation source (Correct answer)
Correct answer: Reducing the time spent near the radiation source
Time is one of the three fundamental principles of radiation protection (Time, Distance, Shielding). By minimizing the duration an individual spends in a radiation field, their total accumulated dose is directly reduced. This is because the total radiation dose is proportional to the exposure time, meaning shorter times result in less exposure.
Question 52: What document must a licensee maintain to ensure accountability of each sealed source in its possession?
- Survey log
- Shipping manifest
- Source inventory record (Correct answer)
- Personnel dosimetry report
Correct answer: Source inventory record
10 CFR 34.31 requires licensees to maintain an inventory record for each sealed source to ensure continuous accountability.
Question 53: What should be done if a dosimeter shows an exposure level above the recommended limit?
- Continue working as usual
- Increase the time spent in the radiation area
- Ignore the reading
- Report the exposure to the radiation safety officer (RSO) immediately (Correct answer)
Correct answer: Report the exposure to the radiation safety officer (RSO) immediately
If a dosimeter indicates an exposure level above the recommended limit, immediate action is required to protect the worker and investigate the incident. The first and most critical step is to report this overexposure to the Radiation Safety Officer (RSO). The RSO will initiate an investigation, assess the situation, and implement corrective actions to prevent recurrence and ensure worker safety.
Question 54: Which type of dosimeter provides a cumulative record of radiation exposure over time?
- Electronic personal dosimeter (EPD)
- Thermoluminescent dosimeter (TLD)
- Film badge dosimeter
- All of the above (Correct answer)
Correct answer: All of the above
Electronic personal dosimeters (EPDs), film badge dosimeters, and thermoluminescent dosimeters (TLDs) are all types of personal dosimeters used to provide a cumulative record of radiation exposure over time. Each type has different mechanisms for measuring and storing dose information, but their common purpose is to track an individual's total radiation intake. They are essential tools for long-term exposure monitoring in radiation environments.
Question 55: What is the primary purpose of conducting a radiation survey before starting radiographic operations?
- To detect and measure radiation levels in the work area (Correct answer)
- To assess the surrounding temperature
- To determine the exposure time needed
- To check the humidity levels
Correct answer: To detect and measure radiation levels in the work area
A radiation survey is a critical safety step performed before starting radiographic operations. Its primary purpose is to identify and quantify radiation levels in the immediate work environment and surrounding areas. This ensures that controlled area boundaries are correctly established and that no unexpected radiation hazards exist, protecting both workers and the public.
Question 56: A radiographic exposure device is discovered missing from a locked vehicle at a job site. After securing personal safety, what is the radiographer's most critical immediate notification?
- Immediately notify the licensee's Radiation Safety Officer (RSO). (Correct answer)
- Immediately notify local law enforcement to report the theft.
- Immediately call other radiographers in the area to help search for the device.
- Immediately notify the client for whom the radiographic work was being performed.
Correct answer: Immediately notify the licensee's Radiation Safety Officer (RSO).
According to regulatory protocol and company procedures, the RSO must be the first point of contact within the company. The RSO is responsible for initiating the company's emergency response plan, which includes making the required notifications to regulatory agencies (like the NRC or Agreement State) and coordinating with law enforcement. The radiographer's primary duty is to report up their chain of command.
Question 57: What is the first step that should be taken if a radiation source becomes stuck or unshielded during a radiographic operation?
- Ignore the issue and proceed
- Attempt to fix the source immediately
- Evacuate the area and notify the radiation safety officer (RSO) (Correct answer)
- Continue the operation as planned
Correct answer: Evacuate the area and notify the radiation safety officer (RSO)
If a radiation source becomes stuck or unshielded, it represents an immediate and serious radiation hazard. The absolute first step is to ensure the safety of personnel by evacuating the area immediately to prevent further exposure. Concurrently, the Radiation Safety Officer (RSO) must be notified so they can manage the emergency with appropriate expertise and equipment.
Question 58: Under 10 CFR Part 34, when performing radiography at a temporary job site, a qualified radiographer must be accompanied by at least one other individual. What is the minimum qualification for this second individual?
- Another certified radiographer.
- A certified Radiation Safety Officer (RSO).
- An individual who has met the requirements of a radiographer's assistant. (Correct answer)
- An individual with security guard training.
Correct answer: An individual who has met the requirements of a radiographer's assistant.
10 CFR 34.41(a) requires that when radiography is performed at a location other than a permanent installation, the radiographer must be accompanied by at least one other qualified radiographer or a radiographer's assistant. This ensures a second person is present who can observe, provide immediate assistance, and prevent unauthorized entry.
Question 59: The amount of shielding material required to reduce the intensity of a gamma ray beam to one-half of its original value is known as the:
- Linear Attenuation Coefficient
- Tenth-Value Layer (TVL)
- Half-Value Layer (HVL) (Correct answer)
- Specific Gamma-Ray Constant
Correct answer: Half-Value Layer (HVL)
The Half-Value Layer (HVL) is the defined thickness of a specific material that will reduce the intensity of a radiation beam by 50%. For example, adding one HVL of lead will cut the beam's intensity in half.
Question 60: Which of the following is an example of a somatic effect of radiation exposure?
- Cataract formation in the exposed individual (Correct answer)
- Birth defects in the exposed individual's offspring
- Mutations in reproductive cells that can be passed on
- Hereditary diseases in future generations
Correct answer: Cataract formation in the exposed individual
Somatic effects are those that affect the body of the exposed individual during their lifetime. Cataracts, skin burns, and cancer are all examples of somatic effects. Genetic (or heritable) effects are those that occur in the reproductive cells and can be passed on to offspring.
Question 61: Why is it important to conduct radiographic operations during off-hours or in isolated areas?
- To increase productivity
- To allow for more time near the radiation source
- To reduce the risk of accidental exposure to non-radiography personnel (Correct answer)
- To minimize the need for protective equipment
Correct answer: To reduce the risk of accidental exposure to non-radiography personnel
Conducting radiographic operations during off-hours or in isolated areas is a key administrative control for radiation safety. This practice minimizes the presence of non-radiography personnel, significantly reducing the chance of accidental exposure to individuals unaware of the hazards. It helps to ensure that only trained and authorized personnel are in the vicinity of the radiation source.
Question 62: Which of the following is NOT an appropriate action during a radiation emergency?
- Following established emergency procedures
- Evacuating the area immediately
- Notifying the RSO and emergency services
- Attempting to contain the source without proper equipment (Correct answer)
Correct answer: Attempting to contain the source without proper equipment
During a radiation emergency, attempting to contain a radiation source without proper training, equipment, and authorization is extremely dangerous and inappropriate. Such actions can lead to severe personal overexposure and worsen the situation. The correct procedure is to evacuate, notify the RSO and emergency services, and allow trained professionals with specialized equipment to handle the source.
Question 63: Which of the following actions is a mandatory and critical safety step that must be performed *immediately* after the source has been retracted into the exposure device and before approaching it?
- Performing a thorough survey of the exposure device and guide tube. (Correct answer)
- Locking the crank assembly.
- Recording the exposure time in the logbook.
- Disconnecting the guide tube.
Correct answer: Performing a thorough survey of the exposure device and guide tube.
It should never be assumed that the source has returned to its shielded position simply because the crank indicates it has. A thorough radiation survey of the entire exposure device and the full length of the guide tube with a calibrated survey meter is the only way to confirm the source is secure. This is a fundamental step to prevent accidental overexposure.
Question 64: What is a 'pig' in the context of industrial radiography source management?
- The lead collimator attached to the front of an exposure device
- A portable shielded container used to store or transport sealed sources (Correct answer)
- The connecting cable between the control console and exposure head
- A contaminated source that cannot be used
Correct answer: A portable shielded container used to store or transport sealed sources
A 'pig' is a portable, heavily shielded container (typically lead or depleted uranium) used to safely store and transport a single sealed source.
Question 65: The three fundamental principles for controlling external radiation exposure, often associated with the ALARA concept, are:
- Calibration, Surveying, and Leak Testing
- Monitoring, Documentation, and Reporting
- Time, Distance, and Shielding (Correct answer)
- Alpha, Beta, and Gamma
Correct answer: Time, Distance, and Shielding
The three cardinal principles of radiation protection to keep doses As Low As Reasonably Achievable (ALARA) are minimizing the time of exposure, maximizing the distance from the source, and using appropriate shielding between the source and the individual.
Question 66: Which of the following events at a temporary job site would require the licensee to make an *immediate* report to the NRC or Agreement State Operations Center?
- An event that causes an individual to receive an actual or threatened whole-body dose of 25 rem (0.25 Sv) or more. (Correct answer)
- A fire on-site that requires the evacuation of personnel but does not damage any radiographic equipment.
- The discovery that a survey meter's calibration due date was passed by one day.
- An individual's alarming ratemeter goes off, but their pocket dosimeter shows a negligible reading.
Correct answer: An event that causes an individual to receive an actual or threatened whole-body dose of 25 rem (0.25 Sv) or more.
According to 10 CFR 20.2202, a licensee must immediately report any event that may have caused or threatens to cause an individual to receive a total effective dose equivalent of 25 rems (0.25 Sv) or more. The other scenarios, while potentially requiring action or internal reporting, do not meet the criteria for immediate notification to the regulatory agency.
Question 67: Which of the following is a primary principle of radiation protection in industrial radiography?
- Ignoring exposure limits
- Increase exposure time
- Shielding with appropriate materials (Correct answer)
- Reduce the distance from the radiation source
Correct answer: Shielding with appropriate materials
Shielding is a fundamental principle of radiation protection, alongside time and distance. It involves placing a barrier of appropriate material, such as lead or concrete, between the radiation source and personnel. This barrier absorbs or scatters radiation, significantly reducing exposure levels and protecting individuals from harmful effects.
Question 68: A licensee must perform inspection and maintenance on radiographic exposure devices, storage containers, and survey instruments. How often must operability checks be performed on a survey meter?
- Only when the batteries are changed
- Once per week
- Before use on each day the equipment is to be used (Correct answer)
- During the quarterly inventory check
Correct answer: Before use on each day the equipment is to be used
According to 10 CFR 34.31, the licensee must perform visual and operability checks on survey meters before use on each day the equipment is to be used. This ensures the instrument is functioning correctly before any radiographic operations begin.
Question 69: Which of the following is considered a stochastic effect of radiation exposure?
- Skin erythema (reddening)
- Cataract formation
- Cancer (Correct answer)
- Nausea and vomiting
Correct answer: Cancer
Stochastic effects are those for which the probability of occurrence increases with dose, but the severity is independent of the dose. Cancer is the primary stochastic effect of concern in radiation protection. The other options are deterministic (or tissue reaction) effects, which have a dose threshold and whose severity increases with dose.
Question 70: Which of the following is the defining characteristic of the Transport Index (TI) on a radioactive materials package?
- The total activity of the source in Curies (Ci).
- The maximum radiation level in mrem/hr at one meter from the package surface. (Correct answer)
- The thickness of the shielding material in inches.
- The maximum radiation level in mrem/hr at the package surface.
Correct answer: The maximum radiation level in mrem/hr at one meter from the package surface.
The Transport Index (TI) is explicitly defined in 49 CFR 173.403 as the dimensionless number equivalent to the maximum radiation level in millirem per hour (mrem/hr) at 1 meter (3.3 ft) from the external surface of the package, rounded up to the next tenth.
Question 71: An industrial radiography crew successfully performs an emergency retrieval of a disconnected source. Which of the following is a mandatory action the licensee must take after the event?
- Re-certify all personnel involved in the retrieval within 48 hours.
- Submit a written report detailing the event to the NRC or Agreement State within 30 days. (Correct answer)
- Take the exposure device out of service permanently, regardless of its condition.
- Issue a press release to the local media explaining the situation and the successful retrieval.
Correct answer: Submit a written report detailing the event to the NRC or Agreement State within 30 days.
According to 10 CFR 34.101, an unintentional disconnection of the source assembly from the control cable is an incident that requires the licensee to send a written report to the regulatory agency within 30 days of the occurrence. This report must detail the cause, corrective actions, and other specifics of the event.
Question 72: What should be done if a worker is accidentally exposed to a high dose of radiation?
- Evacuate the worker, seek medical attention immediately, and report to the RSO (Correct answer)
- Continue working without taking any action
- Increase the exposure to other workers to balance the dose
- Ignore the exposure and finish the task
Correct answer: Evacuate the worker, seek medical attention immediately, and report to the RSO
In the event of a high radiation exposure, the immediate priority is the affected worker's health and safety. The worker must be evacuated from the radiation area, and immediate medical attention sought to assess and treat potential radiation injuries. Simultaneously, the incident must be reported to the Radiation Safety Officer (RSO) for investigation and regulatory compliance.
Question 73: A radiographer is performing a survey and the meter's needle goes off-scale to the right on the x1 scale. What is the immediate, correct action for the radiographer to take?
- Turn the range selector switch to a higher multiplication factor (e.g., x10 or x100). (Correct answer)
- Move the meter further away from the source until a reading is obtained.
- Assume the meter is saturated and immediately exit the area.
- Note the reading as 'maximum' and complete the survey.
Correct answer: Turn the range selector switch to a higher multiplication factor (e.g., x10 or x100).
When a survey meter's reading goes 'off-scale' or 'pegs' to the right, it means the radiation field is greater than the maximum reading on the current scale. The proper procedure is to switch to a less sensitive, higher range (e.g., from x1 to x10, or x10 to x100) to obtain an accurate measurement of the dose rate. This is a normal part of operating a multi-scale survey meter.
Question 74: A radiographer prepares to transport a package containing a radiographic source. A survey of the package reveals a maximum radiation level of 35 mrem/hr at the surface and 0.7 mrem/hr at one meter. According to 49 CFR 172.403, what is the correct radioactive label for this package?
- RADIOACTIVE YELLOW-II (Correct answer)
- SPECIAL PERMIT
- RADIOACTIVE YELLOW-III
- RADIOACTIVE WHITE-I
Correct answer: RADIOACTIVE YELLOW-II
According to 49 CFR 172.403, the label is determined by the higher of two conditions: the surface dose rate and the Transport Index (TI), which is the dose rate at 1 meter. A RADIOACTIVE YELLOW-II label is required when the surface dose rate is greater than 0.5 mrem/hr but not more than 50 mrem/hr, AND the TI is not more than 1. Since 35 mrem/hr is within the surface limit and the TI of 0.7 is within the TI limit, YELLOW-II is the correct label.
Question 75: According to 10 CFR Part 20, what is the annual occupational dose limit for the whole body of an adult radiographer?
- 5,000 mrem (50 mSv) (Correct answer)
- 500 mrem (5 mSv)
- 100 mrem (1 mSv)
- 50,000 mrem (500 mSv)
Correct answer: 5,000 mrem (50 mSv)
10 CFR Part 20, 'Standards for Protection Against Radiation,' sets the annual total effective dose equivalent for the whole body of an adult radiation worker at 5,000 mrem (50 mSv).
Question 76: How long must sealed source inventory records be retained under NRC regulations?
- 5 years after the record is made
- 3 years after the record is made (Correct answer)
- 1 year after the record is made
- Until the license expires
Correct answer: 3 years after the record is made
10 CFR 34.87 specifies that records of sealed source inventory must be retained for 3 years after the record is made.
Question 77: What is the primary safety function of the locking mechanism on a radiographic exposure device?
- To provide a secondary method of retracting the source.
- To indicate if the device has been tampered with.
- To prevent unauthorized use and secure the source in its shielded position. (Correct answer)
- To prevent the drive gear from wearing out.
Correct answer: To prevent unauthorized use and secure the source in its shielded position.
The lock's main purpose is to secure the sealed source within its shielded container, preventing accidental exposure or unauthorized operation of the device. This is a critical administrative and engineering control for radiation safety.
Question 78: After retracting a source, a radiographer's survey meter shows readings significantly above background along the guide tube and at the exposure device. This indicates the source is not properly shielded. After securing the restricted area, what is the radiographer's NEXT step?
- Immediately notify the Radiation Safety Officer (RSO) and follow the established emergency procedure. (Correct answer)
- Attempt to crank the source out and back in again quickly.
- Replace the battery in the survey meter and re-survey the equipment.
- Use long-handled tongs to disconnect the guide tube from the device.
Correct answer: Immediately notify the Radiation Safety Officer (RSO) and follow the established emergency procedure.
If the source fails to return to the fully shielded position, it is an abnormal event that requires initiating the company's emergency procedures. The first steps are always to secure the area to prevent further exposure and then immediately contact the RSO for guidance. Attempting to manipulate the equipment without a specific plan can worsen the situation.
Question 79: Which of the following records must a licensee maintain regarding industrial radiographic operations?
- The personal contact information of every client
- Quarterly inventory of sealed sources (Correct answer)
- A list of all radiographs taken
- Daily vehicle mileage logs to job sites
Correct answer: Quarterly inventory of sealed sources
According to 10 CFR Part 34, licensees are required to conduct a physical inventory of all sealed sources every three months (quarterly) to ensure they are accounted for.
Question 80: How frequently must radiographers physically account for all sealed sources in their possession to ensure source security?
- Daily at shift start
- Monthly inventory audits
- Before and after each use (Correct answer)
- Weekly at minimum
Correct answer: Before and after each use
Radiographers must account for all sealed sources before and after each use to immediately detect any loss or potential theft of radioactive material.
Question 81: During a source change on an exposure device, what is the primary radiological concern for the radiographer performing the procedure?
- Occupational dose exposure during the source exchange procedure (Correct answer)
- The new source may arrive with surface contamination from the manufacturer
- The old source may cross-contaminate the new source during transfer
- The guide tube may become permanently radioactively activated
Correct answer: Occupational dose exposure during the source exchange procedure
Source change procedures place the radiographer closer to an unshielded source than virtually any other task, making occupational dose management the primary radiological concern.
Question 82: Deterministic effects of radiation, such as skin erythema or sterility, are characterized by which of the following?
- A threshold dose below which the effect is not observed (Correct answer)
- A linear, no-threshold dose-response relationship
- The probability of occurrence being the primary concern, not the severity
- The severity of the effect being independent of the dose received
Correct answer: A threshold dose below which the effect is not observed
Deterministic effects (also called tissue reactions) are characterized by a threshold dose; the effect will not occur unless a certain minimum dose is received. Once that threshold is exceeded, the severity of the effect increases with the dose. This is in contrast to stochastic effects, which have no threshold.
Question 83: What is the required method for disposing of a depleted or unwanted sealed source used in industrial radiography?
- Bury it on-site after confirming dose rate is below background
- Transfer it to a licensed recipient, waste broker, or return it to the manufacturer (Correct answer)
- Submerge it in a designated water-filled shielding tank indefinitely
- Dispose of it in a municipal landfill after surveying with a calibrated instrument
Correct answer: Transfer it to a licensed recipient, waste broker, or return it to the manufacturer
Sealed sources must be transferred to a licensed recipient such as a radioactive waste broker, distributor, or manufacturer for proper regulatory disposal.
Question 84: A radiographer needs to perform a 10-minute task in a radiation field of 120 mrem/hr. What is the total dose the radiographer will receive?
- 20 mrem (Correct answer)
- 1200 mrem
- 12 mrem
- 60 mrem
Correct answer: 20 mrem
Total dose is calculated by multiplying the dose rate by the exposure time. First, convert the time to hours (10 minutes / 60 minutes/hour = 1/6 hour). Then, multiply the dose rate by the time: 120 mrem/hr * (1/6) hr = 20 mrem.
Question 85: A radiographer is driving a company vehicle to a job site with a properly secured and labeled radiographic device. According to 49 CFR 177.817, where must the shipping papers be located during transportation?
- In a locked glove compartment.
- Taped securely to the outside of the transport package.
- In the back of the vehicle, next to the exposure device.
- Within the driver's immediate reach when restrained by a seatbelt. (Correct answer)
Correct answer: Within the driver's immediate reach when restrained by a seatbelt.
DOT regulations require that shipping papers for hazardous materials be readily accessible to authorities in an emergency. 49 CFR 177.817 specifies that when the driver is at the vehicle's controls, the papers must be within their immediate reach while restrained by the lap and shoulder belt, and either readily visible or in a holder mounted to the inside of the door.
Question 86: What is the required immediate action if a sealed source leak test yields removable contamination above the regulatory limit?
- Increase the survey frequency and continue operations
- Wait for additional activity decay before retesting
- Remove the source from service immediately and notify the NRC (Correct answer)
- Perform a second confirmatory leak test before taking action
Correct answer: Remove the source from service immediately and notify the NRC
A leaking source must be immediately withdrawn from service and the NRC notified per 10 CFR 34.27, as a failed leak test indicates a loss of source containment.
Question 87: Which safety measure should always be taken when setting up a radiographic operation?
- Ignoring distance from the radiation source
- Using personal dosimeters (Correct answer)
- Removing all protective barriers
- Increasing exposure time
Correct answer: Using personal dosimeters
Using personal dosimeters is a mandatory and fundamental safety measure for anyone involved in radiographic operations. These devices continuously monitor and record an individual's radiation exposure, providing crucial data to ensure doses remain within safe limits. They are essential for tracking cumulative exposure and verifying the effectiveness of other safety protocols.
Question 88: Which of the following is a key component of an emergency response plan for radiographic operations?
- Guidelines for working without PPE
- Protocols for notifying emergency personnel and the RSO (Correct answer)
- Procedures for increasing exposure
- Instructions to ignore alarms
Correct answer: Protocols for notifying emergency personnel and the RSO
A key component of any effective emergency response plan for radiographic operations is clear protocols for communication. This includes detailed instructions on how and when to notify emergency personnel (e.g., fire department, medical services) and, crucially, the Radiation Safety Officer (RSO). Prompt and accurate notification ensures that appropriate resources are deployed to manage the incident safely.
Question 89: A radiographer is preparing to transport a radiographic exposure device to a field location. Which set of regulations primarily governs the placarding of the vehicle and the shipping papers?
- ANSI N432-1980
- NRC 10 CFR Part 34
- DOT 49 CFR Parts 171-173 (Correct answer)
- OSHA 29 CFR 1910.1096
Correct answer: DOT 49 CFR Parts 171-173
The U.S. Department of Transportation (DOT) regulations, specifically 49 CFR, govern the transportation of hazardous materials, including radioactive sources. These regulations cover requirements for packaging, labeling, placarding of vehicles, and shipping papers.
ASNT Industrial Radiography Radiation Safety Personnel (IRRSP) Exam
The ASNT IRRSP exam certifies personnel in radiation safety for industrial radiography, covering radiation fundamentals, protection principles, equipment operation, regulations, and emergency procedures per NRC 10 CFR Part 34.
Exam Rules
- You can skip questions and return to them later
- Flag questions for review before submitting
- No feedback shown until you submit the entire exam
- Unanswered questions count as wrong — answer everything
- 10 pretest questions are mixed in and don't affect your score
- Timer auto-submits when time runs out
- Your progress is auto-saved every 30 seconds