  1. What is the minimum slope required for a horizontal drain pipe to ensure proper drainage by gravity?

    Answer: 1/4 inch per foot

    A minimum slope of 1/4 inch per foot (2%) is required for horizontal drain pipes 3 inches or smaller to maintain adequate flow velocity.

  2. A home inspector observes a water heater with no pressure relief valve discharge pipe. What is the primary concern?

    Answer: Steam and hot water could spray dangerously if the valve opens

    Without a discharge pipe, an opening T&P valve could spray scalding water or steam directly at occupants, posing a serious burn hazard.

  3. What does a home inspector look for when checking an air conditioning evaporator coil?

    Answer: Ice buildup or blocked condensate drain

    Ice on the evaporator coil indicates restricted airflow or low refrigerant, and a blocked condensate drain can cause water damage or system shutdown.

  4. Which type of pipe is most commonly identified by its blue or black color and is acceptable for potable cold-water supply lines?

    Answer: PEX

    PEX (cross-linked polyethylene) is commonly color-coded blue for cold water and red for hot water, and is approved for potable water supply.

  5. An inspector finds a gas furnace with a cracked heat exchanger. What is the recommended course of action?

    Answer: Recommend immediate discontinuation of use and professional repair

    A cracked heat exchanger can allow carbon monoxide to mix with supply air and enter living spaces, making it a life-safety issue requiring immediate action.

  6. What is the purpose of a backflow preventer on a hose bibb (exterior faucet)?

    Answer: To prevent contaminated water from siphoning back into the potable supply

    A backflow preventer (vacuum breaker) stops contaminated water — such as from a garden hose left in a chemical solution — from being siphoned back into the home's potable water supply.

  7. When inspecting supply ducts in an unconditioned attic, an inspector should be most concerned about:

    Answer: Missing or inadequate insulation on ducts

    Uninsulated ducts in a hot attic lose significant conditioned air energy and can cause condensation, reducing system efficiency and potentially causing moisture damage.