Insulation and Ventilation Flashcards

7 cards from real INTERNACHI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Insulation and Ventilation flashcards as text
  1. What is the R-value per inch for closed-cell spray polyurethane foam insulation?

    Answer: R-6 to R-7 per inch

    Closed-cell spray polyurethane foam typically provides R-6 to R-7 per inch, the highest R-value per inch among commonly used insulation types.

  2. Which condition is most likely to cause 'wind washing' in an attic insulation system?

    Answer: Inadequate soffit vent area compared to ridge vent area

    When ridge vent area exceeds soffit vent area, negative pressure can draw outside air under the insulation at the eaves, degrading its R-value through wind washing.

  3. What does the 'net free area' of a vent refer to?

    Answer: The actual open area through which air can pass, excluding frame and screen

    Net free area is the actual unobstructed opening through which air flows, which is always less than the gross vent dimensions due to frames, louvers, and screens.

  4. A home inspector observes ice dams on the eaves of a house after a winter storm. Which attic condition most likely contributed to their formation?

    Answer: Heat escaping through inadequate or missing attic insulation warming the roof deck

    Heat escaping from the living space through insufficient attic insulation warms the roof deck, melting snow that refreezes at the cold eaves and forms ice dams.

  5. What is the primary function of insulation baffles (rafter vents) installed in attic eave areas?

    Answer: To maintain a clear airway from soffit vents to the attic space above insulation

    Baffles create a channel that keeps soffit vent airflow clear of blown or batt insulation that might otherwise block the eave ventilation pathway.

  6. Which class of vapor retarder has a perm rating of 0.1 or less?

    Answer: Class I

    Class I vapor retarders, such as sheet polyethylene and glass, have a perm rating at or below 0.1, making them the most restrictive category.

  7. When inspecting a crawl space with a ground vapor barrier, what deficiency should an inspector note if the barrier is not sealed at the perimeter walls?

    Answer: Moisture will migrate from exposed soil edges into the crawl space air

    Ground vapor barriers must be sealed or lapped up the foundation walls to prevent soil moisture from evaporating around the edges and entering the crawl space.