โ† All HVAC Flashcard Decks

Energy Efficiency Flashcards

7 cards from real HVAC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Energy Efficiency flashcards as text
  1. What is 'heat recovery ventilation' (HRV) and how does it save energy?

    Answer: It transfers heat between exhaust and incoming fresh air streams, reducing the energy needed to condition ventilation air

    HRVs use a heat exchanger to pre-condition incoming fresh air with energy from the outgoing exhaust air, reducing the heating or cooling load on the HVAC system.

  2. Which action will most improve the seasonal efficiency of a split-system air conditioner?

    Answer: Ensuring the outdoor unit is shaded and has adequate airflow clearance

    Shading the condenser and ensuring unrestricted airflow lowers entering air temperature, reducing condensing pressure and improving efficiency throughout the season.

  3. What is the purpose of 'duct static pressure reset' control in a VAV system?

    Answer: To reduce duct static pressure setpoint when zone damands are low, saving fan energy

    Static pressure reset lowers the duct pressure setpoint when VAV boxes are mostly open, allowing the supply fan VFD to slow down and save energy.

  4. A technician finds that a chilled water system has fouled heat exchangers. What is the energy impact?

    Answer: Increased chiller lift (higher condenser temperature or lower evaporator temperature), reducing chiller efficiency

    Fouling adds thermal resistance, forcing the chiller to operate at a higher lift (greater temperature difference between condenser and evaporator), which directly reduces COP.

  5. Which energy code compliance path allows a trade-off between building envelope and HVAC efficiency?

    Answer: Performance path (energy modeling to meet a total energy budget)

    The performance compliance path uses whole-building energy modeling, allowing a less efficient envelope to be offset by a more efficient HVAC system as long as total energy use meets the budget.

  6. What effect does high indoor relative humidity have on HVAC energy efficiency?

    Answer: It increases latent load, requiring additional cooling capacity and energy to dehumidify the air

    High humidity adds latent load to the system; removing moisture requires additional cooling energy, often requiring overcooling the space or supplemental dehumidification.

  7. What is 'setback' or 'setup' control in HVAC energy management?

    Answer: Temporarily relaxing temperature setpoints during unoccupied periods to reduce heating or cooling energy

    Setback (heating) and setup (cooling) raise or lower thermostat setpoints when a building is unoccupied, reducing HVAC runtime and energy consumption significantly.