  1. What is the correct workflow sequence in a sterile processing department?

    Answer: Decontamination, Assembly/Inspection, Sterilization, Sterile Storage, Distribution

    SPD workflow follows unidirectional flow from soiled to clean through five stages.

  2. Why is positive air pressure maintained in sterile storage relative to corridors?

    Answer: To prevent unfiltered air from entering when doors open

    Positive pressure causes air to flow outward when doors open, preventing corridor contamination.

  3. What is a count sheet or pick list used for?

    Answer: Documenting exact instruments and quantities for each tray set

    Count sheets list every instrument and quantity for each tray, guiding assembly and verification.

  4. What is event-related sterility maintenance?

    Answer: Sterility is maintained until an event compromises packaging integrity

    Properly packaged items remain sterile until an event compromises the barrier.

  5. What key metrics should an SPD quality program track?

    Answer: Sterilization failure rates, cleaning verification, defect rates, tray errors, IUSS usage, and turnaround times

    Comprehensive QA tracks metrics across all process areas including sterilization, cleaning, assembly, and IUSS.

  6. What does 'sterile to sterile, unsterile to unsterile' mean in distribution?

    Answer: Sterile items must only contact sterile items/surfaces; unsterile items kept separate

    This principle ensures sterile items contact only sterile surfaces and remain separated from non-sterile items.