  1. What is the purpose of a wind-washing barrier behind insulation in an attic knee wall?

    Answer: To prevent wind from reducing insulation effectiveness

    Wind washing occurs when air movement through insulation reduces its thermal resistance; a rigid barrier on the cold side prevents this.

  2. Which climate zone(s) typically require a continuous air barrier but NOT a vapor retarder on the interior?

    Answer: Climate Zones 1-2 (hot-humid)

    In hot-humid climates, interior vapor retarders can trap moisture inside assemblies; an air barrier alone is the recommended moisture control strategy.

  3. What is the minimum net free area ratio required for ventilation chutes (baffles) in a vented attic per IRC?

    Answer: 1:150 of the attic floor area

    IRC Section R806 requires a minimum net free ventilating area of 1:150 unless conditions allow 1:300 with balanced high/low distribution.

  4. In HERS ratings, what is the correct term for the total area of all surfaces separating conditioned space from unconditioned space or outdoors?

    Answer: Thermal envelope area

    The thermal envelope encompasses all surfaces—walls, roof, floors, windows, and doors—that bound the conditioned space.

  5. A rim joist is a common air leakage site in older homes. Which insulation method best addresses both air sealing and thermal performance at the rim joist?

    Answer: Spray foam applied directly to the rim joist

    Spray foam conforms to irregular surfaces, seals all gaps, and provides insulation in a single step, making it ideal for rim joists.

  6. What does the term 'effective R-value' account for that nominal R-value does not?

    Answer: Thermal bridging through framing members

    Effective R-value accounts for the reduced whole-assembly thermal resistance caused by thermal bridging through studs, joists, and other framing elements.

  7. Which of the following is classified as an air-impermeable insulation per ASTM E2178?

    Answer: Closed-cell spray polyurethane foam

    Closed-cell spray foam has an air permeance ≤0.02 L/(s·m²) at 75 Pa, meeting the ASTM E2178 definition of air-impermeable insulation.