← All G3 Flashcard Decks

G3 - Gas Technician Level 3 Appliance Installation and Service Questions and Answers Flashcards

6 cards from real G3 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 G3 - Gas Technician Level 3 Appliance Installation and Service Questions and Answers flashcards as text
  1. What is the minimum clearance from combustible materials typically required when installing a gas-fired forced-air furnace in the US?

    Answer: Follow manufacturer's listed clearances

    Appliance clearances must follow the manufacturer's listed installation instructions, which are based on testing and listing by a recognized authority.

  2. Before lighting a gas appliance pilot, a technician should first:

    Answer: Check that the area is free of gas odor and purge any accumulated gas

    Purging accumulated gas and confirming no gas odor prevents ignition of a potentially explosive mixture.

  3. When installing a gas dryer, the flexible connector between the dryer and the house piping must be:

    Answer: Approved for gas use and not concealed inside walls

    Gas connectors for appliances must be listed for gas service and must remain accessible, not run inside walls or floors.

  4. Which type of valve must be installed within 6 feet of a gas appliance and be accessible for shutoff?

    Answer: Manual shutoff valve

    A manual shutoff valve must be located within 6 feet of each appliance and remain readily accessible to quickly cut off gas supply in an emergency.

  5. When connecting a gas range in the US, the appliance connector should be:

    Answer: A listed flexible metal connector no longer than 6 feet

    ANSI Z21.69/CSA 6.16 requires listed flexible connectors for gas ranges, limited to 6 feet in length.

  6. A gas appliance that is 'listed' means it has been:

    Answer: Evaluated and certified by a nationally recognized testing laboratory

    A listed appliance has been evaluated against applicable safety standards by an NRTL such as UL or CSA.