Fire Prevention & Hazardous Materials Management Flashcards
7 cards from real FST practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Fire Prevention & Hazardous Materials Management flashcards as text
During a fire prevention inspection of a spray painting booth, which hazard should the inspector prioritize?
Answer: Accumulation of paint residue and inadequate ventilation creating a flammable atmosphere
Flammable paint vapors combined with residue buildup in a poorly ventilated spray booth create explosive concentrations and represent the top fire hazard.
According to NFPA 1, what is the minimum fire flow requirement used during fire prevention inspections to assess adequacy of water supply?
Answer: It varies based on the occupancy type, construction, and area of the building
Minimum fire flow requirements vary with building size, occupancy classification, and construction type, as specified in NFPA 1 and supporting annexes.
When radioactive materials are involved in a hazmat incident, what is the correct initial action for fire personnel without specialized radiological training?
Answer: Establish a safe perimeter, evacuate the area, and request specialized radiological assistance
Unprotected personnel should not approach radiological incidents; establishing a perimeter and summoning specialists protects responders from radiation exposure.
A facility stores compressed chlorine gas cylinders. Under NFPA 1, in what occupancy hazard classification would this storage most likely fall?
Answer: High hazard
Chlorine gas is a toxic and reactive compressed gas; storage of such materials places the occupancy in the high-hazard category under NFPA 1.
What is the role of Local Emergency Planning Committees (LEPCs) under SARA Title III?
Answer: To develop emergency response plans and coordinate community preparedness for hazardous chemical incidents
LEPCs are required by EPCRA (SARA Title III) to develop local emergency response plans addressing hazardous chemical hazards within their planning district.
Which document describes the specific fire and life safety requirements for a building based on its use and occupancy classification under the International Fire Code (IFC)?
Answer: Operational Permit
Under the IFC, an operational permit specifies the conditions and requirements under which a specific high-hazard operation or occupancy may be conducted.
A cryogenic liquid oxygen storage tank is installed at a medical facility. What is the primary fire hazard associated with liquid oxygen?
Answer: It greatly accelerates the burning of ordinary combustibles that come into contact with it
Liquid oxygen is a strong oxidizer that dramatically increases the burn rate of ordinary combustibles, making even materials that normally do not burn intensely flammable.