Free F60 Fire Watch Procedures Questions and Answers 1 — Questions and Answers
Question 1: An F-60 Fire Guard is assigned to a multi-story construction site where torch operations are occurring on the 5th floor. Besides the immediate hot work area, which other location is a critical and mandatory area for this Fire Guard to monitor?
- The roof of the building.
- The floor directly below the torch operations. (Correct answer)
- The main entrance on the first floor.
- The staging area for construction materials.
Correct answer: The floor directly below the torch operations.
The FDNY requires that when hot work is being performed, the Fire Guard is responsible for monitoring the area for fire hazards, including the floors above and below the operation. Sparks and slag can easily fall through openings and start fires on lower levels.
Question 2: A 'Responsible Person' is designated at a hot work site to ensure safety. According to FDNY regulations, which of the following is a primary duty of the Responsible Person BEFORE issuing a hot work authorization?
- Personally operate the fire extinguisher in a drill.
- Notify the local firehouse of the planned work.
- Inspect the hot work site to ensure it is a fire-safe area. (Correct answer)
- Train the F-60 Fire Guard on torch operation techniques.
Correct answer: Inspect the hot work site to ensure it is a fire-safe area.
The FDNY code specifies that the Responsible Person must inspect the hot work area before authorizing any work to begin. This inspection is to ensure that all necessary precautions are in place and the area is free from fire hazards.
Question 3: Which of the following scenarios would automatically prohibit torch operations from beginning, even if an F-60 Fire Guard is present?
- The torch operator is using a brand-new, un-tested torch.
- A portable fire extinguisher has a pressure gauge in the green zone but has not been inspected in 13 months. (Correct answer)
- Combustible materials are located 40 feet away from the hot work.
- The work is scheduled to take place during a light rain shower.
Correct answer: A portable fire extinguisher has a pressure gauge in the green zone but has not been inspected in 13 months.
Portable fire extinguishers must be inspected annually. An extinguisher that has not been inspected within the last 12 months is not considered reliable and its presence would not meet the safety requirements for hot work to commence.
Question 4: An F-60 Fire Guard's duties are critical to site safety. Which of the following tasks is explicitly outside the scope of an F-60 Fire Guard's responsibilities while a fire watch is being conducted?
- Stopping the hot work if unsafe conditions develop.
- Performing other work assignments, such as running errands or moving materials. (Correct answer)
- Communicating with the torch operator about potential hazards.
- Inspecting the area after the hot work is completed.
Correct answer: Performing other work assignments, such as running errands or moving materials.
The F-60 Fire Guard must be dedicated solely to the fire watch. They cannot have any other duties or responsibilities that could distract them from observing the hot work area and identifying potential fire hazards.
Question 5: During a post-operation fire watch, an F-60 Fire Guard discovers a small, smoldering fire. After notifying the FDNY, what is the next appropriate action for the Fire Guard to take?
- Immediately evacuate the entire building.
- Attempt to extinguish the fire with a portable fire extinguisher, if it is limited in size. (Correct answer)
- Leave the area to find the torch operator who performed the work.
- Wait for the FDNY to arrive before taking any action.
Correct answer: Attempt to extinguish the fire with a portable fire extinguisher, if it is limited in size.
Fire Guards are trained in the use of portable fire extinguishers and should attempt to extinguish a fire only when it is small and can be managed without undue risk. After calling 911, taking immediate action to control a small fire is a key responsibility.
Question 6: A citywide permit holder is performing torch operations in a commercial building. The Hot Work Program Authorization, signed by the Responsible Person, must be kept available on-site for inspection. For how long after the work is completed must this document be maintained?
- 24 hours
- 12 hours
- 72 hours
- 48 hours (Correct answer)
Correct answer: 48 hours
According to FDNY regulations, the hot work authorization must be kept available for inspection by any representative of the department during the work and for 48 hours after the work is complete.
An F-60 Fire Guard is assigned to a multi-story construction site where torch operations are occurring on the 5th floor.
Besides the immediate hot work area, which other location is a critical and mandatory area for this Fire Guard to monitor?