Free F60 Fire Guard Duties & Responsibilities Questions and Answers 1 — Questions and Answers
Question 1: An F-60 Fire Guard performing a post-operation inspection notices a small, smoldering fire in a pile of debris 30 minutes after torch operations have ceased. What is the Fire Guard's IMMEDIATE responsibility?
- Document the finding in the fire guard log and inform the supervisor at the end of the shift.
- Immediately extinguish the smoldering fire using a portable fire extinguisher. (Correct answer)
- Leave the area and report the fire to the building's responsible person.
- Wait for the second required post-work inspection before taking any action.
Correct answer: Immediately extinguish the smoldering fire using a portable fire extinguisher.
The primary duty of a Fire Guard is to prevent and extinguish fires. Upon discovering any fire, no matter how small, the immediate action is to extinguish it, if it is safe to do so. Reporting and documentation follow after the immediate hazard is controlled.
Question 2: According to FDNY regulations for torch operations, which of the following is a key duty of the F-60 Fire Guard BEFORE any hot work begins?
- Operating the torch equipment to test its functionality.
- Ensuring the torch operator has the correct citywide permit.
- Inspecting the hot work area to ensure it is clear of combustibles within a 35-foot radius. (Correct answer)
- Training other workers on how to use a fire extinguisher.
Correct answer: Inspecting the hot work area to ensure it is clear of combustibles within a 35-foot radius.
A critical pre-hot work duty for a Fire Guard is to inspect the entire area. This includes verifying that all combustible materials are removed from a 35-foot radius around the work area or are properly shielded with fire-resistant covers.
Question 3: A Fire Guard for torch operations is required to maintain a fire watch for a specific duration AFTER the work has been completed. What is this minimum required duration?
- 15 minutes
- 60 minutes
- Until the area has cooled to room temperature
- 30 minutes (Correct answer)
Correct answer: 30 minutes
FDNY regulations mandate that the fire watch must continue for at least 30 minutes after the completion of torch operations to detect and extinguish any smoldering fires that may have been started by sparks or slag.
Question 4: During a rooftop torch-applied roofing operation, the F-60 Fire Guard's ONLY responsibility is to:
- Assist the roofers with moving materials.
- Perform the fire watch and have no other duties. (Correct answer)
- Monitor the weather conditions for potential rain.
- Ensure the roofing materials are installed correctly.
Correct answer: Perform the fire watch and have no other duties.
The role of the Fire Guard during hot work is dedicated solely to fire prevention and safety. They must not be assigned any other duties that could distract them from continuously monitoring the hot work area for fire hazards.
Question 5: Which of the following must be readily available to the F-60 Fire Guard at all times during torch operations?
- A copy of the building's blueprint.
- The personal cell phone number of the fire commissioner.
- At least one portable fire extinguisher with a minimum 2-A:20-B:C rating. (Correct answer)
- A list of all workers on the construction site.
Correct answer: At least one portable fire extinguisher with a minimum 2-A:20-B:C rating.
FDNY regulations require that at least one portable fire extinguisher with a minimum rating of 2-A:20-B:C be readily accessible to the Fire Guard within 30 feet of the hot work area.
Question 6: An F-60 Fire Guard is responsible for maintaining a fire watch at several locations. Which of the following is NOT a location where an F-60 Fire Guard is specifically required by the FDNY?
- Construction sites.
- Inside a restaurant kitchen during normal cooking operations. (Correct answer)
- On any rooftop where a torch-applied roofing system is being installed.
- In a building where torch operations are conducted by a person holding a citywide permit.
Correct answer: Inside a restaurant kitchen during normal cooking operations.
The F-60 Certificate of Fitness is specifically for fire watch during torch operations. While kitchens have fire risks, the F-60 is not required for routine cooking. It is mandated for construction sites, torch-applied roofing, and any building where a citywide permit holder is performing torch operations.
An F-60 Fire Guard performing a post-operation inspection notices a small, smoldering fire in a pile of debris 30 minutes after torch operations have ceased.
What is the Fire Guard's IMMEDIATE responsibility?