Florida General Contractor Florida General Contractor Mechanical and Electrical Systems 2 — Questions and Answers
Question 1: Under the Florida Building Code, what is the minimum clearance required in front of an electrical panel (switchboard or panelboard)?
- 18 inches
- 24 inches
- 36 inches (Correct answer)
- 48 inches
Correct answer: 36 inches
The NEC (adopted in Florida) requires a minimum 36-inch working clearance in front of electrical panels and switchboards for safe access.
Question 2: What does 'SEER' measure in a Florida HVAC system?
- Sound emission efficiency rating
- Seasonal Energy Efficiency Ratio — a measure of cooling efficiency over a season (Correct answer)
- System equipment energy reserve
- Static energy exchange rate
Correct answer: Seasonal Energy Efficiency Ratio — a measure of cooling efficiency over a season
SEER (Seasonal Energy Efficiency Ratio) measures an air conditioner's cooling output over a typical cooling season divided by the electrical energy it consumes.
Question 3: In Florida, what type of pipe material is typically prohibited for use as supply water piping in residential construction due to historical failure issues?
- CPVC
- Polybutylene (PB) (Correct answer)
- PEX
- Copper type L
Correct answer: Polybutylene (PB)
Polybutylene (PB) pipe was banned from new construction due to widespread failures caused by reaction to oxidants in public water supplies.
Question 4: Which Florida trade license is required to perform air conditioning work on systems with more than 25 tons of cooling capacity?
- Class A Air Conditioning Contractor license (Correct answer)
- Class B Air Conditioning Contractor license
- Mechanical Contractor license
- Registered HVAC technician certificate
Correct answer: Class A Air Conditioning Contractor license
A Class A Air Conditioning Contractor license in Florida is required for unlimited tonnage, including systems over 25 tons of cooling capacity.
Question 5: What is the minimum slope (grade) for a horizontal drain pipe in a Florida plumbing system for pipes 3 inches or less in diameter?
- 1/16 inch per foot
- 1/8 inch per foot
- 1/4 inch per foot (Correct answer)
- 1/2 inch per foot
Correct answer: 1/4 inch per foot
The Florida Plumbing Code requires horizontal drain pipes 3 inches or less in diameter to slope at a minimum of 1/4 inch per foot toward the drain.
Question 6: Under the Florida Building Code, what is required when an air handler unit is installed in an attic space to prevent water damage from condensate overflow?
- A secondary drain pan with a separate drain line or overflow switch (Correct answer)
- A float valve on the primary drain only
- Insulation wrap on the drain pan only
- An overflow alarm audible from outside the building
Correct answer: A secondary drain pan with a separate drain line or overflow switch
Florida requires a secondary drain pan with a separate condensate drain line or an overflow safety switch when air handlers are installed in attic spaces.
Under the Florida Building Code, what is the minimum clearance required in front of an electrical panel (switchboard or panelboard)?