What is the minimum number of cylinders that must be cast per concrete test per FDOT requirements for acceptance testing?
Answer: 2
FDOT requires a minimum of 2 cylinders per test set for acceptance, with one tested at 28 days and one held as a check cylinder.
According to FDOT, what is the maximum allowable slump for vibrated concrete in bridge deck construction?
Answer: 4 inches
FDOT specifications limit slump to a maximum of 4 inches for vibrated concrete used in bridge deck construction.
What does FDOT Class V concrete designation indicate?
Answer: High-strength structural concrete above 6,000 psi
FDOT Class V concrete is high-strength concrete with specified compressive strengths exceeding 6,000 psi, used for high-performance applications.
When should a concrete inspector reject a load of ready-mix concrete arriving on an FDOT project?
Answer: All of the above
FDOT specifications require rejection if any of these conditions are met: excessive drum revolutions, time limit exceeded, or concrete temperature too high.
What FDOT specification requires contractors to submit a concrete mix design for approval before use?
Answer: Section 346
FDOT Section 346 requires contractors to submit mix designs for engineer approval prior to beginning concrete placement operations.
According to FDOT guidelines, what is the maximum concrete free-fall height permitted during placement to prevent segregation?
Answer: 6 feet
FDOT limits free-fall height to 6 feet maximum during concrete placement to prevent segregation of aggregates from the paste.