Fire Prevention and Inspection Flashcards
7 cards from real FDNY practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Fire Prevention and Inspection flashcards as text
Which NYC Fire Code provision requires buildings to submit a Fire Safety and Evacuation Plan?
Answer: FC 404
NYC Fire Code Section 404 (FC 404) mandates that certain buildings prepare and submit a Fire Safety and Evacuation Plan detailing procedures for occupant notification, evacuation, and fire response.
An FDNY inspector finds electrical extension cords used as permanent wiring in a commercial kitchen. This violates fire code primarily because:
Answer: Permanent use creates an overheating and fire ignition hazard
Extension cords used as permanent wiring are a fire hazard because they are not designed for continuous load, leading to overheating, insulation damage, and potential ignition.
Under the NYC Fire Code, how must exit signs be illuminated in a place of assembly?
Answer: By a dedicated circuit with emergency backup power
Exit signs must be illuminated by a dedicated circuit connected to an emergency backup power source so they remain visible during a power failure or fire emergency.
The FDNY Certificate of Fitness for a Citywide Sprinkler System Coordinator (F-58) is required in buildings with:
Answer: Buildings required to maintain a fire pump under the Fire Code
An F-58 Citywide Sprinkler System Coordinator Certificate of Fitness is required for individuals responsible for overseeing sprinkler systems in buildings that must maintain a fire pump under NYC Fire Code.
What action should a fire inspector take upon discovering an improperly stored compressed gas cylinder not secured against tipping?
Answer: Issue a violation notice and require immediate corrective action
An unsecured compressed gas cylinder is an immediately correctable fire hazard; the inspector should issue a violation notice and require the owner to secure the cylinder before leaving the premises.
According to the NYC Fire Code, what minimum width must a required means of egress corridor maintain?
Answer: 44 inches
The NYC Fire Code requires required egress corridors to maintain a minimum clear width of 44 inches to allow safe passage of building occupants during an evacuation.
Which document must be posted at the main entrance of a building undergoing hot work operations?
Answer: A Hot Work Permit issued by the FDNY Bureau of Fire Prevention
A Hot Work Permit issued by the FDNY Bureau of Fire Prevention must be obtained and posted at the site before any welding, cutting, or other hot work operations begin.