← All FCE Flashcard Decks

Sincerity of Effort & Symptom Validity Flashcards

7 cards from real FCE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Sincerity of Effort & Symptom Validity flashcards as text
  1. The coefficient of variation (CV) threshold most commonly used in grip strength testing to indicate consistent, reliable effort is:

    Answer: Less than 15%

    A CV of less than 15% across repeated grip strength trials is the widely accepted criterion indicating consistent, sincere effort.

  2. In the five-position grip strength test, a bell-shaped curve of results (low-high-low pattern) across positions 1 through 5 is considered a sign of:

    Answer: Sincerity of maximal effort

    A bell-shaped curve where grip strength peaks at position 2 or 3 and tapers at the extremes is the normal pattern indicating sincere maximal effort.

  3. The Rapid Exchange Grip (REG) test is used in FCE primarily to:

    Answer: Detect submaximal effort by comparing REG to sustained grip values

    The REG test compares rapid-alternating grip values to sustained grip; submaximal effort is suggested when REG values are unexpectedly higher than sustained grip values.

  4. Waddell's non-organic signs are used in FCE to assess:

    Answer: Behavioral indicators that may suggest symptom magnification

    Waddell's signs are behavioral and physical exam findings that may indicate non-organic contributions to pain and disability, signaling possible symptom magnification.

  5. Which of the following is the MOST appropriate term for a clinical finding when an examinee performs below their actual physical ability during FCE testing?

    Answer: Submaximal effort

    Submaximal effort is the clinically appropriate, objective term; malingering implies intent to deceive, which FCE evaluators cannot definitively determine.

  6. Heart rate monitoring during FCE testing is used as a sincerity of effort indicator because:

    Answer: Submaximal effort typically produces a disproportionately low heart rate relative to reported exertion

    When an examinee reports maximal effort and severe pain yet demonstrates a low cardiovascular response, this physiological inconsistency suggests submaximal effort.

  7. Which consistency criterion indicates reliable performance during range-of-motion testing in an FCE?

    Answer: All three repeated measurements within 5 degrees of each other

    ROM reliability is typically established when three repeated measurements fall within 5 degrees of each other, demonstrating consistent, reproducible effort.