โ† All ETC Flashcard Decks

Safety Standards & Regulatory Compliance Flashcards

7 cards from real ETC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Safety Standards & Regulatory Compliance flashcards as text
  1. A technician must work within the Limited Approach Boundary of energized electrical equipment. According to NFPA 70E, who may enter this boundary?

    Answer: Qualified persons or unqualified persons escorted by a qualified person

    NFPA 70E defines the Limited Approach Boundary as a shock protection boundary that unqualified persons may cross only when accompanied by a qualified person.

  2. Under the EPA's RMP (Risk Management Program) rule, facilities handling certain hazardous chemicals above threshold quantities must submit which document?

    Answer: Risk Management Plan

    EPA's 40 CFR Part 68 requires facilities with regulated substances above threshold quantities to develop and submit a Risk Management Plan.

  3. What distinguishes an 'administrative control' from an 'engineering control' in hazard mitigation?

    Answer: Administrative controls change work practices or schedules; engineering controls physically alter the work environment

    Engineering controls physically modify equipment or the environment to reduce hazard exposure, while administrative controls involve changes to work procedures, schedules, or practices.

  4. Which fire class designation applies to energized electrical equipment fires?

    Answer: Class C

    Class C fires involve energized electrical equipment, requiring non-conductive extinguishing agents to avoid shock hazard.

  5. OSHA's Process Safety Management (PSM) standard (29 CFR 1910.119) applies to facilities that handle highly hazardous chemicals at or above what threshold?

    Answer: Threshold quantities specified in Appendix A of the standard

    PSM applicability is triggered when a facility has a listed highly hazardous chemical at or above the threshold quantities in 29 CFR 1910.119 Appendix A.

  6. When calibrating test instruments used for safety-critical measurements, which documentation is required to demonstrate traceability?

    Answer: Calibration certificates traceable to NIST or equivalent national standards

    Metrological traceability requires calibration certificates that link measurements back to national or international standards bodies such as NIST.

  7. A worker receives a chemical splash to the eyes. According to OSHA's First Aid requirements (29 CFR 1910.151), the immediate response should be to flush the eyes for a minimum of how long?

    Answer: 15 minutes

    OSHA and ANSI/ISEA Z358.1 recommend continuous flushing of the eyes for a minimum of 15 minutes after chemical splash exposure.