  1. What is the key difference between refrigerant 'recovery' and 'reclamation'?

    Answer: Recovery removes refrigerant from a system; reclamation reprocesses it to AHRI 700 purity standards

    Recovery extracts refrigerant from a system into a container for storage or transport, while reclamation involves reprocessing that recovered refrigerant to meet AHRI Standard 700 purity specifications before it can be resold.

  2. To which purity standard must reclaimed refrigerant conform before it can legally be resold or reused?

    Answer: AHRI Standard 700

    AHRI Standard 700 specifies the purity requirements that reclaimed refrigerants must meet before they can be resold or reused in HVAC/R equipment to ensure system compatibility.

  3. When is a technician legally permitted to skip refrigerant recovery before opening an A2L refrigerant system for repair?

    Answer: There are no exemptions — recovery is always required before opening any system

    EPA Section 608 contains no exemption based on charge size, leak rate, or disposal status; refrigerant recovery is required before opening any system containing regulated refrigerants.

  4. What paperwork is required when transporting recovered A2L refrigerant cylinders to a reclamation facility?

    Answer: Proper DOT shipping papers (bill of lading) and compliant hazmat labeling

    DOT regulations classify refrigerants as hazardous materials, requiring proper shipping papers (bill of lading) and compliant hazmat labeling on cylinders during transport to any reclamation facility.

  5. What is the primary environmental benefit of properly reclaiming A2L refrigerants rather than disposing of them?

    Answer: It reduces the need to manufacture new virgin refrigerant, conserving resources and limiting HFC emissions

    Reclaiming and reusing refrigerant reduces demand for newly manufactured HFCs, thereby lowering the greenhouse gas emissions associated with refrigerant production and preventing atmospheric release.

  6. Which of the following correctly describes the EPA's requirement for recovered refrigerant cylinders used during A2L system service?

    Answer: DOT-approved recovery cylinders must be used and must not be overfilled beyond 80% capacity

    EPA and DOT regulations require the use of DOT-approved recovery cylinders that must not be filled beyond 80% of their capacity by volume to allow for thermal expansion and safe transport.