MVAC System Components & Operation Flashcards
6 cards from real EPA 609 practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 6 MVAC System Components & Operation flashcards as text
What does a typical MVAC manifold gauge set measure?
Answer: Both high-side and low-side pressures simultaneously
A manifold gauge set has two gauges — a blue low-side gauge and a red high-side gauge — to simultaneously monitor both system pressures.
What is a typical low-side pressure reading for a properly charged R-134a MVAC system at idle?
Answer: 25–45 psi
A properly functioning R-134a system typically shows 25–45 psi on the low side at idle in normal ambient conditions.
What is a typical high-side pressure reading for a properly charged R-134a MVAC system?
Answer: 150–250 psi
The high side of an R-134a system typically operates between 150–250 psi depending on ambient temperature and load.
What causes abnormally HIGH low-side pressure and HIGH high-side pressure in an MVAC system?
Answer: Overcharge or condenser cooling failure
Both pressures being high indicates an overcharged system or a condenser that cannot reject heat properly.
Which service port connects to the LOW side of an MVAC system?
Answer: The larger port (typically near the compressor inlet/accumulator)
The low-side service port is larger and is located on the suction side of the compressor or near the accumulator.
A sight glass showing bubbles in an R-134a system indicates:
Answer: The system may be low on refrigerant
Bubbles in the sight glass indicate that refrigerant is not fully liquid at that point, suggesting a low charge or restriction.