Cardiovascular Evaluation & Monitoring Flashcards
7 cards from real ECC practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Cardiovascular Evaluation & Monitoring flashcards as text
Which lead configuration is considered the best single lead for detecting ST-segment changes during continuous cardiac monitoring?
Answer: Lead V5
Lead V5 is the most sensitive single lead for detecting ST-segment changes, particularly myocardial ischemia involving the lateral wall.
A patient's arterial blood gas shows pH 7.28, PaCO2 52 mmHg, HCO3 24 mEq/L. What is the primary acid-base disturbance?
Answer: Respiratory acidosis
The elevated PaCO2 with normal bicarbonate indicates primary respiratory acidosis without metabolic compensation.
During 12-lead ECG acquisition, what is the recommended paper speed for standard recording?
Answer: 25 mm/sec
The standard ECG paper speed is 25 mm/sec, making each small square represent 0.04 seconds.
Which hemodynamic finding is most consistent with cardiac tamponade?
Answer: Pulsus paradoxus >10 mmHg
Pulsus paradoxus greater than 10 mmHg — an exaggerated fall in systolic BP during inspiration — is a hallmark finding of cardiac tamponade.
On a cardiac monitor, artifact mimicking ventricular fibrillation is most commonly caused by which of the following?
Answer: Patient shivering or muscle tremor
Shivering or skeletal muscle tremor produces high-frequency artifact that can closely resemble the chaotic baseline of ventricular fibrillation.
What does a prolonged QTc interval (>500 ms) primarily indicate in the context of ECC?
Answer: Increased risk of torsades de pointes
A QTc greater than 500 ms significantly increases the risk of torsades de pointes, a potentially fatal polymorphic ventricular tachycardia.
When auscultating heart sounds, an S3 gallop in an adult patient most commonly suggests:
Answer: Ventricular volume overload or heart failure
An S3 gallop in adults indicates rapid ventricular filling against a non-compliant ventricle, most commonly associated with heart failure or volume overload.