โ† All DCI Flashcard Decks

Standards and Codes Flashcards

7 cards from real DCI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Standards and Codes flashcards as text
  1. Which pair combination is used for pins 1 and 2 in the T568B wiring standard?

    Answer: Orange pair

    In T568B, pins 1 and 2 use the orange/white-orange pair, which differs from T568A where pins 1 and 2 use the green/white-green pair.

  2. When must a fiber optic installation conform to ANSI/TIA-568.3-D rather than 568.2-D?

    Answer: When installing optical fiber cabling components

    ANSI/TIA-568.3-D is the specific standard for optical fiber cabling components and applies whenever fiber optic cable is being installed.

  3. A cable installer is working in a high-rise building and must run cable vertically between floors. Which NEC cable rating is appropriate for this application?

    Answer: CMR

    CMR (Communications Multipurpose Riser) rated cable is required for vertical runs between floors because it prevents fire from traveling up through the building via the cable jacket.

  4. According to ANSI/TIA-568, the maximum distance from a horizontal cross-connect to a telecommunications outlet in a single-tenant building is:

    Answer: 90 meters

    The horizontal cabling subsystem allows a maximum of 90 meters for the permanent link, from the HC (Horizontal Cross-connect) to the TO (Telecommunications Outlet).

  5. What is the primary purpose of the ANSI/TIA-758-B standard?

    Answer: Customer-owned outside plant cabling

    ANSI/TIA-758-B covers customer-owned outside plant (OSP) telecommunications infrastructure, including cabling between buildings on a campus.

  6. Under IEEE 802.3bt (PoE++), what is the maximum power that can be delivered over a single 4-pair cable?

    Answer: 90 watts

    IEEE 802.3bt Type 4 (PoE++) specifies up to 90 watts of power delivery over a 4-pair cable, requiring Category 6A or better cabling.

  7. Which fire code organization publishes the Life Safety Code (NFPA 101) that affects telecommunications installations in buildings?

    Answer: NFPA (National Fire Protection Association)

    NFPA publishes NFPA 101 (Life Safety Code), which governs means of egress and fire safety requirements that impact how cabling can be routed through buildings.