โ† All CTS Flashcard Decks

AV Site Surveys Flashcards

7 cards from real CTS practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 AV Site Surveys flashcards as text
  1. During a site survey, you note that the planned control system rack location is 280 feet from the primary display. Why is this distance critical to document?

    Answer: It affects signal type selection, since some unbalanced video signals degrade over long runs

    Long cable runs can cause signal degradation, requiring the design team to specify signal extenders, fiber, or appropriate cable types rated for that distance.

  2. An AV site survey checklist should include verification of which fire and life safety element relevant to AV cabling?

    Answer: Fire-stop ratings of wall and floor penetrations where cables will pass

    Any new cable penetration through a rated fire barrier must be fire-stopped to maintain the wall or floor assembly's fire rating, as required by building and fire codes.

  3. When conducting a site survey for outdoor AV installation, which environmental factor most directly affects equipment enclosure specification?

    Answer: Ingress Protection (IP) rating requirements based on exposure to moisture and dust

    Outdoor environments expose equipment to rain, humidity, and dust, requiring enclosures and devices with appropriate IP ratings to prevent damage.

  4. A surveyor photographs an existing ceiling-mounted speaker layout in a space being renovated. What is the primary purpose of these photographs in the project record?

    Answer: To provide as-existing documentation so the design team can assess reuse, relocation, or removal needs

    Photographs of existing conditions help the design team evaluate whether existing equipment can be reused or must be relocated or removed during renovation.

  5. During a site survey, you identify that the planned display wall is an exterior-facing wall with fiberglass batt insulation. What concern should be noted for the design team?

    Answer: Wall-mount anchoring may need to reach structural studs or blocking, which could be offset from standard spacing

    Exterior walls may have non-standard stud spacing or blocking, and insulation cavities require hardware that can reach structural members for safe mounting loads.

  6. A site survey for a boardroom reveals a marble floor and plaster ceiling with no soft furnishings. Which acoustic treatment recommendation is most appropriate to note?

    Answer: Add absorptive panels or soft surfaces to reduce flutter echo and excessive reverberation

    Hard parallel surfaces cause flutter echo and long reverb times; absorptive treatment is needed to achieve acceptable speech intelligibility.

  7. When documenting network infrastructure during an AV site survey, which piece of information is most critical for IP-based AV control system design?

    Answer: Available switch port count, VLAN configuration, and whether PoE is supported

    IP-controlled AV devices require switch ports with proper VLAN segmentation and often PoE for touchpanels and IP cameras, making these parameters essential to document.