← All CPT Flashcard Decks

Shelf Life & Product Protection Flashcards

7 cards from real CPT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Shelf Life & Product Protection flashcards as text
  1. Which unit is most commonly used to express Moisture Vapor Transmission Rate (MVTR) in packaging films?

    Answer: g/m²/day

    MVTR is most commonly expressed as grams of water vapor transmitted per square meter per day (g/m²/day) under defined temperature and humidity conditions.

  2. The Oxygen Transmission Rate (OTR) of a packaging material is critical for products that are susceptible to oxidative rancidity. Which of the following materials has the LOWEST OTR?

    Answer: Ethylene vinyl alcohol (EVOH)

    EVOH (ethylene vinyl alcohol) provides an exceptionally low oxygen transmission rate, making it one of the best barrier materials against oxygen permeation.

  3. In accelerated shelf life testing (ASLT), the Arrhenius equation is used to predict product shelf life at ambient temperature. What does the Q10 factor represent?

    Answer: The increase in reaction rate for a 10°C rise in temperature

    Q10 is the factor by which the rate of a chemical or biological reaction increases with a 10°C rise in temperature, typically ranging from 2 to 3 for most food quality degradation reactions.

  4. Water activity (aw) is a critical parameter for predicting microbial shelf life. Which aw level represents the threshold below which most bacteria cannot grow?

    Answer: 0.91

    Most spoilage and pathogenic bacteria cannot grow below an aw of approximately 0.91, making this a critical threshold for microbial safety and shelf life.

  5. Which type of packaging test measures the rate at which gases permeate through a film under a partial pressure differential?

    Answer: Gas permeation test

    Gas permeation testing directly measures the transmission rate of gases (O₂, CO₂, N₂) through a packaging film driven by the partial pressure difference across the film.

  6. Headspace gas analysis is performed on sealed packages to verify the atmosphere inside. Which instrument is most commonly used for this purpose?

    Answer: Gas chromatograph or O₂/CO₂ analyzer

    Gas chromatography or dedicated O₂/CO₂ analyzers are standard instruments used to measure headspace gas composition in sealed food and beverage packages.

  7. A food manufacturer wants to calculate the shelf life of a product stored at 25°C using data obtained from testing at 35°C and 45°C. This approach is known as:

    Answer: Accelerated shelf life testing (ASLT)

    Accelerated shelf life testing (ASLT) uses elevated temperature (and sometimes humidity) conditions to speed up degradation reactions, then applies models like Arrhenius to predict shelf life at lower, real-world temperatures.