Measurement & Calibration Flashcards
7 cards from real CPT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Measurement & Calibration flashcards as text
A micrometer reads 0.752 inches but the actual dimension is 0.750 inches. This 0.002-inch error is best described as:
Answer: Systematic error
A consistent offset from the true value is a systematic error, often caused by instrument miscalibration or a zero offset.
Which of the following best describes 'measurement traceability'?
Answer: An unbroken chain of comparisons linking measurements to national or international standards
Traceability means every measurement can be connected through an unbroken calibration chain to a recognized standard such as NIST.
When calibrating a pressure gauge, the technician compares it against a deadweight tester. The deadweight tester is serving as the:
Answer: Reference standard
The deadweight tester provides a known, accurate pressure value against which the gauge being calibrated is compared, making it the reference standard.
A dial indicator has a resolution of 0.001 inch. What does resolution mean in this context?
Answer: The smallest increment the instrument can display or detect
Resolution is the smallest change in the measured quantity that the instrument can distinguish and display.
A Go/No-Go gage is used to check a shaft diameter. The shaft passes the Go end but fails the No-Go end. What does this result indicate?
Answer: The shaft is within specification
A part that passes (enters) the Go gage and does not pass (enter) the No-Go gage is within the specified tolerance range.
Which environmental factor most commonly causes thermal expansion errors in precision measurement?
Answer: Temperature
Temperature changes cause materials to expand or contract, directly affecting dimensional measurements; the industry standard reference temperature is 68°F (20°C).
A technician records five measurements of the same part: 2.501, 2.500, 2.502, 2.499, 2.500. The average is 2.5004. This instrument demonstrates:
Answer: Low accuracy and high precision
The readings are tightly clustered (high precision) but the average is slightly above the true value, indicating a small systematic offset (lower accuracy).