← All CPSI Flashcard Decks

Hazard Identification and Assessment Questions and Answers Flashcards

7 cards from real CPSI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Hazard Identification and Assessment Questions and Answers flashcards as text
  1. A CPSI inspector encounters a slide with a 10-inch wide chute and no contained sides for the first 24 inches of the descent. What standard is most likely violated?

    Answer: ASTM F1487 — equipment containment and side height requirements

    ASTM F1487 requires slide chutes to have side containment of adequate height to prevent children from rolling off the edges during descent.

  2. During a high-frequency inspection, a CPSI finds that a belt swing has twisted chains that reduce the seat height by 6 inches below the standard 24-inch minimum. What is the most appropriate action?

    Answer: Untwist the chains and verify seat height meets the 24-inch minimum before returning to service

    Twisted chains are correctable on-site; the inspector should untwist them and verify the seat height is restored to the minimum 24-inch clearance.

  3. A CPSI inspector is assessing a composite play structure for 2-5 year olds. A horizontal ladder rung is spaced 18 inches apart. How should this be classified?

    Answer: Entrapment hazard — rung spacing exceeds the maximum allowed for this age group

    Rung spacing for 2-5 year old equipment must not exceed 12 inches to prevent children from falling through between rungs.

  4. Which environmental factor should a CPSI inspector always consider when evaluating natural shade trees within a playground use zone?

    Answer: Whether overhanging branches, roots, or falling debris create hazards within the use zone

    Overhanging branches can fall, surface roots create tripping hazards, and falling debris (nuts, seeds, branches) can injure children within the use zone.

  5. A CPSI inspector finds a tunnel on a playground where the interior diameter is 23 inches. What is the primary concern this raises?

    Answer: The diameter is below the 24-inch minimum, creating an entrapment risk for larger children

    Tunnels must have a minimum 24-inch interior diameter per ASTM F1487 to prevent children from becoming entrapped inside.

  6. When a CPSI inspector uses a template gauge and discovers an opening measures 4.5 inches in a deck structure, what hazard classification applies?

    Answer: Head entrapment hazard — the opening falls within the 3.5 to 9 inch entrapment zone

    Openings between 3.5 and 9 inches are classified as head entrapment hazards because a child's head can enter but may not exit the opening.

  7. A CPSI inspector is documenting findings at the end of a site visit. Which hazard classification requires the inspector to notify the playground owner or operator BEFORE leaving the site?

    Answer: Imminent hazards that pose an immediate risk of serious injury or death

    Imminent hazards require immediate notification to the owner/operator before the inspector leaves so that the equipment can be taken out of service immediately.