CPR CPR Odor Control & Deodorization 2 — Questions and Answers
Question 1: What is the primary purpose of an air scrubber (negative air machine) during smoke odor remediation?
- To heat the structure for drying
- To filter airborne particulates and odor-laden air using HEPA and activated carbon filters (Correct answer)
- To inject ozone into the work area
- To measure VOC levels in the air
Correct answer: To filter airborne particulates and odor-laden air using HEPA and activated carbon filters
Air scrubbers draw contaminated air through HEPA and carbon filtration stages, capturing particulates and adsorbing volatile organic compounds that carry odors.
Question 2: Which biological odor situation calls for an EPA-registered antimicrobial applied BEFORE deodorization?
- Cigarette smoke odor in walls
- Category 3 sewage intrusion with microbial contamination (Correct answer)
- Cooking odors in kitchen cabinets
- Pet dander odors in carpet
Correct answer: Category 3 sewage intrusion with microbial contamination
Category 3 water (sewage) contains pathogens; antimicrobial treatment must precede deodorization to address the biological source, not just the smell.
Question 3: Activated carbon filtration in air scrubbers works by which mechanism?
- Chemical oxidation of VOC molecules
- Adsorption — VOC molecules physically bond to the large porous carbon surface (Correct answer)
- UV photolysis of odor compounds
- HEPA mechanical filtration of gas molecules
Correct answer: Adsorption — VOC molecules physically bond to the large porous carbon surface
Activated carbon captures VOCs through adsorption, where gas-phase molecules adhere to the extensive internal surface area of porous carbon granules.
Question 4: After ozone treatment ends and the area is ventilated, how is residual ozone best confirmed safe before re-occupancy?
- Wait 15 minutes and rely on the smell
- Test with a calibrated ozone meter until levels fall below 0.1 ppm OSHA PEL (Correct answer)
- Run an air scrubber for 1 hour
- Open all windows for 5 minutes
Correct answer: Test with a calibrated ozone meter until levels fall below 0.1 ppm OSHA PEL
OSHA's permissible exposure limit for ozone is 0.1 ppm (8-hour TWA); a calibrated meter confirms safe levels before occupants return.
Question 5: A restorer detects a strong musty odor after completing Category 2 water mitigation. The MOST likely source is:
- Residual cleaning chemical off-gassing
- Microbial growth (mold/bacteria) in remaining wet materials (Correct answer)
- Ozone from equipment left running
- Glue off-gassing from new flooring installed nearby
Correct answer: Microbial growth (mold/bacteria) in remaining wet materials
Musty odors following water damage are a hallmark sign of microbial amplification in materials that remained wet beyond the 24–48 hour window.
Question 6: Which standard governs professional smoke and odor remediation procedures for restorers in the US?
- NFPA 921
- IICRC S770 Standard for Professional Smoke Remediation (Correct answer)
- OSHA 29 CFR 1910.134
- EPA 40 CFR Part 61
Correct answer: IICRC S770 Standard for Professional Smoke Remediation
The IICRC S770 Standard for Professional Smoke Remediation establishes the industry's technical requirements for smoke and odor assessment and remediation.