← All CPE Flashcard Decks

Safety & Environmental Compliance Flashcards

7 cards from real CPE practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Safety & Environmental Compliance flashcards as text
  1. Which OSHA standard specifically governs the lockout/tagout (LOTO) of energy sources during equipment servicing?

    Answer: 29 CFR 1910.147

    29 CFR 1910.147, the Control of Hazardous Energy standard, mandates lockout/tagout procedures to protect workers during servicing and maintenance.

  2. A plant burns coal and must comply with EPA's National Ambient Air Quality Standards (NAAQS). Which pollutant is NOT classified as a criteria pollutant under the Clean Air Act?

    Answer: Hydrogen sulfide (H₂S)

    EPA's six criteria pollutants are SO₂, CO, NO₂, O₃, PM2.5/PM10, and Pb; hydrogen sulfide is not among them.

  3. Under SARA Title III (EPCRA), what is the purpose of Tier II reporting?

    Answer: Providing local emergency planners with hazardous chemical inventory data

    EPCRA Section 312 Tier II reports give Local Emergency Planning Committees (LEPCs) annual inventory data on hazardous chemicals stored at facilities.

  4. Which type of fire extinguisher is appropriate for a Class D (combustible metal) fire in a plant environment?

    Answer: Dry sand or specific metal-fire agent extinguisher

    Class D fires involving metals like magnesium or titanium require dry sand or a dry powder agent specifically rated for combustible metals, as water or CO₂ can worsen the fire.

  5. What is the permissible exposure limit (PEL) concept established by OSHA, and how does it differ from ACGIH's TLV?

    Answer: PELs are legally enforceable 8-hour TWA limits; TLVs are advisory consensus values often more current

    OSHA PELs are legally binding standards set in 29 CFR 1910.1000, while ACGIH TLVs are consensus-based guidelines that are typically updated more frequently and are often more protective.

  6. A new chemical process is being designed. At which stage is it most cost-effective to apply inherently safer design (ISD) principles?

    Answer: During initial conceptual and process design phase

    Inherently safer design is most effective and least costly when applied during conceptual design, before equipment is specified or built.

  7. Under the Resource Conservation and Recovery Act (RCRA), a 'large quantity generator' must dispose of hazardous waste within how many days of accumulation?

    Answer: 90 days

    RCRA regulations allow large quantity generators a maximum of 90 days to accumulate hazardous waste on-site before it must be sent to a permitted treatment, storage, or disposal facility.