  1. Which remote monitoring technology allows continuous ambulatory tracking of hemodynamic parameters in heart failure patients via an implanted pulmonary artery pressure sensor?

    Answer: CardioMEMS HF System

    The CardioMEMS HF System is an implanted wireless sensor that measures pulmonary artery pressure to guide heart failure management remotely.

  2. When a cardiac catheterization laboratory's hemodynamic monitoring system displays a damped arterial waveform, the FIRST troubleshooting step should be:

    Answer: Flush the arterial line with heparinized saline

    A damped waveform typically indicates a clot or air bubble at the catheter tip, so flushing the line is the appropriate first step.

  3. In cardiac MRI, the term 'late gadolinium enhancement' (LGE) refers to:

    Answer: Myocardial fibrosis or scar tissue that retains contrast agent longer than normal tissue

    LGE reflects areas where gadolinium is retained due to disrupted cell membranes or expanded extracellular space, indicating fibrosis or scar.

  4. A fractional flow reserve (FFR) value of 0.75 measured during coronary angiography indicates:

    Answer: Hemodynamically significant stenosis warranting revascularization

    An FFR ≤0.80 indicates hemodynamically significant ischemia; values ≤0.75 clearly indicate revascularization benefit.

  5. Which software algorithm used in modern ECG systems automatically measures the QT interval and flags prolongation?

    Answer: Glasgow algorithm

    The Glasgow algorithm is a widely used automated ECG interpretation system that measures intervals including QTc and flags abnormalities.

  6. In electrophysiology, a 3D electroanatomic mapping system creates a cardiac chamber map using:

    Answer: Magnetic field sensors in the catheter tip correlated with fluoroscopic position

    Systems like CARTO use magnetic field-based localization of catheter tip sensors to construct real-time 3D maps of cardiac chambers.

  7. Which technology is used in transcatheter aortic valve replacement (TAVR) planning to calculate annulus dimensions and optimal fluoroscopic angles?

    Answer: CT angiography with dedicated TAVR planning software

    CT angiography with specialized planning software (e.g., 3Mensio, Vida) provides precise annulus sizing, calcium scoring, and coplanar angle calculation for TAVR.