โ† All CHI Flashcard Decks

Property Maintenance & Operations Flashcards

7 cards from real CHI practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Property Maintenance & Operations flashcards as text
  1. An inspector finds that a bathroom exhaust fan vents into the attic space. This is a problem because:

    Answer: Moisture discharged into the attic can cause mold and structural damage

    Bathroom fans must vent to the exterior; venting into attic spaces introduces moisture that promotes mold growth and wood decay.

  2. What is the MAIN purpose of a sacrificial anode rod in a storage water heater?

    Answer: To prevent corrosion of the tank lining through galvanic sacrifice

    The magnesium or aluminum anode rod corrodes preferentially, protecting the steel tank from rust through cathodic protection.

  3. A home inspector observes that the main electrical panel neutral bar is bonded to the cabinet enclosure. This is:

    Answer: Correct only in a main service panel, not subpanels

    In a main service panel the neutral-to-ground bond is required, but in subpanels the neutral must be isolated from the enclosure to prevent parallel neutral paths.

  4. Which type of roof flashing is installed in a stepped pattern along a sloped roof-to-wall junction?

    Answer: Step flashing

    Step flashing consists of individual L-shaped pieces installed in overlapping steps at the intersection of a sloped roof and a vertical wall.

  5. During an inspection you find that the kitchen sink drain trap is installed WITHOUT a trap arm connecting it to the drain in the wall. What is the concern?

    Answer: Sewer gases can enter the living space without proper venting

    Without a proper drain configuration, the water seal in the trap can be siphoned away, allowing sewer gases to enter the home.

  6. What is the recommended minimum clearance between the bottom of a wood structural member and the soil in a crawlspace?

    Answer: 18 inches

    A minimum 18-inch clearance between wood structural members and soil is required to allow inspection access and prevent wood contact with moisture.

  7. An inspector notices that a downspout discharges directly against the foundation wall. The BEST recommendation is to:

    Answer: Extend the downspout at least 6 feet away from the foundation

    Downspouts should discharge water at least 6 feet from the foundation, either via extensions or underground drains, to prevent foundation moisture problems.