Question 1: Space utilization studies typically use which technology to capture real-time occupancy data?
- Thermal imaging cameras for energy audits
- IoT occupancy sensors and badge access data (Correct answer)
- Manual clipboard-based head counts only
- Structural load sensors
Correct answer: IoT occupancy sensors and badge access data
IoT occupancy sensors (PIR, ultrasonic, CO2-based) combined with badge/Wi-Fi access data provide continuous, scalable utilization measurement across large portfolios.
Question 2: What does a 'churn rate' measure in the context of workplace facility management?
- Employee turnover percentage
- The percentage of the workforce that moves, adds, or changes workstations in a year (Correct answer)
- Equipment replacement frequency
- HVAC filter replacement intervals
Correct answer: The percentage of the workforce that moves, adds, or changes workstations in a year
Churn rate tracks how often the FM team must relocate employees or reconfigure workspaces, directly impacting move management costs and planning resources.
Question 3: Which space planning tool is used to show the flow and adjacency relationships between departments before finalizing a floor plan?
- Bubble diagram (Correct answer)
- Gantt chart
- Pareto chart
- Critical path method diagram
Correct answer: Bubble diagram
Bubble diagrams use circles proportional to space requirements and connecting lines to illustrate desired departmental adjacencies during early programming.
Question 4: Under ASHRAE 62.1, minimum ventilation rates for office spaces are based primarily on which two factors?
- Building height and floor area
- Occupant density and floor area (Correct answer)
- Number of HVAC units and ceiling height
- Outdoor air quality and window area
Correct answer: Occupant density and floor area
ASHRAE 62.1 calculates minimum outdoor air requirements using a people component (cfm per person Ă— occupant density) plus an area component (cfm per square foot).
Question 5: A facility manager is asked to calculate the seats-to-headcount ratio for a 500-person company using 400 workstations. What is the ratio?
- 0.8:1 (Correct answer)
- 1.25:1
- 1:0.8
- 5:4
Correct answer: 0.8:1
Dividing 400 seats by 500 employees yields a 0.8:1 ratio, meaning there are 20% fewer seats than staff — typical in hybrid environments with assumed absence.
Question 6: Which document captures all space programming requirements—room types, areas, adjacencies, and special conditions—before design begins?
- Building information model
- Architectural program (Correct answer)
- Space utilization report
- Certificate of occupancy
Correct answer: Architectural program
An architectural program (or facility program) documents all functional requirements and constraints that the design must satisfy, serving as the brief for architects and planners.