Subfloor Assessment & Preparation Flashcards

7 cards from real CFI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Subfloor Assessment & Preparation flashcards as text
  1. Which condition in an existing vinyl composition tile (VCT) floor may indicate the presence of asbestos?

    Answer: Tiles that are 9×9 inches and installed before 1980

    9×9-inch VCT tiles and their adhesive installed before 1980 commonly contained asbestos and must be tested before disturbance.

  2. What is the recommended acclimation period and environment for hardwood flooring before installation?

    Answer: 3–5 days at 60–80°F with 30–50% RH matching occupied conditions

    Hardwood must acclimate at living conditions (60–80°F, 30–50% RH) for 3–5 days so it reaches equilibrium moisture content before installation.

  3. When is it necessary to install a vapor retarder under a wood subfloor over a crawl space?

    Answer: Whenever the crawl space is unconditioned or has exposed soil

    Exposed soil in an unconditioned crawl space is a major moisture source; a polyethylene vapor retarder is required to protect the wood subfloor above.

  4. A plywood subfloor panel has face checking (surface cracks). What is the appropriate action before installing hardwood over it?

    Answer: Fill the checks with floor patching compound and allow to cure

    Surface checks must be filled and flattened so they don't telegraph through or create weak points in the finished floor.

  5. What is the primary reason for staggering end joints of subfloor panels by at least 4 feet?

    Answer: To prevent a continuous joint line that creates a weak point or ridge

    Staggering end joints distributes stress and prevents a continuous weak line that could crack finishes or create a noticeable ridge.

  6. Which type of concrete slab condition would require mechanical scarification rather than chemical etching before adhesive application?

    Answer: A slab with an existing sealer or curing compound on the surface

    Surface sealers and curing compounds create a bond-breaking film that chemical etching cannot fully remove, requiring scarification to achieve a clean, porous surface.

  7. Subfloor squeaks in a wood-framed floor are MOST commonly caused by what condition?

    Answer: Movement between the subfloor panel and the joist due to inadequate fastening or gaps

    Squeaks result from panels rubbing against joist tops or fasteners loosening over time, causing friction noise with foot traffic.