CFESA Cheat Sheet 2026

The 30 highest-yield CFESA facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.

100 questions
120 min time limit
70% to pass
  1. Which repair is indicated when a commercial glass door merchandiser has condensation forming on the exterior of the glass during normal operation? Inspect and replace the door glass anti-sweat heater circuit or increase its duty cycle
  2. When using a clamp meter to diagnose a commercial cooking appliance, a technician measures amp draw significantly above nameplate rating. This indicates: A possible short circuit, failed component drawing excess current, or mechanical binding
  3. Which business metric should a food equipment service technician track to demonstrate value when seeking a promotion to lead technician? First-call completion rate and customer satisfaction scores
  4. A commercial combi-oven displays an error for high steam chamber pressure. After verifying the drain is clear, what component should be inspected? The steam generator pressure relief valve and pressure transducer
  5. What does the EPA's SNAP (Significant New Alternatives Policy) program regulate? New refrigerants and substitutes for ozone-depleting substances
  6. Which tool is commonly used to measure electrical components in commercial food equipment? Multimeter
  7. What is the correct manifold pressure for commercial LP (propane) gas equipment? 11 inches W.C.
  8. When repairing a commercial soft-serve machine that produces product with excessive air incorporation (too foamy), which component is most likely at fault? The overrun adjustment valve or air pump system delivering too much air to the mix
  9. A commercial refrigerator compressor hums but does not start. The technician confirms proper voltage at the compressor terminals. What should be tested first? Start relay and start capacitor
  10. During commissioning of a new gas convection oven, the CO reading in the flue gases is 800 ppm air-free. What action is required? Shut down the appliance immediately and do not operate until repaired
  11. A food establishment is cited for having a reach-in cooler that does not maintain proper temperature. Which regulatory body most likely issued the citation? Local health department
  12. How does earning manufacturer-specific factory training typically benefit a CFESA technician's career? It qualifies the technician as an authorized service provider for that brand
  13. How can CFESA-certified technicians improve operational efficiency during service calls? By conducting thorough diagnostics and having common parts on hand
  14. What is the primary purpose of a phase-loss protection relay in three-phase commercial food equipment? To shut down the equipment if one of the three supply phases is lost
  15. When calibrating a commercial convection oven thermostat, a technician finds it reads 25°F high. The correct action is: Adjust the calibration screw per manufacturer specification to correct the offset
  16. When transitioning from a field technician role to a service manager position, which skill is most critical to develop? Team leadership and personnel management
  17. A technician measures a high head pressure and normal suction pressure in a walk-in cooler. The most likely cause is: Dirty condenser coils
  18. What is the correct procedure for re-torquing cylinder head bolts on a commercial food equipment compressor after initial repair? Torque cold in a star pattern to spec, then recheck after first thermal cycle
  19. When performing PM on a commercial tilting skillet (braising pan), a technician should lubricate the: Tilt mechanism pivot points and gear assembly per manufacturer specifications
  20. Which NSF standard specifically governs the design and construction of commercial warewashing equipment? NSF/ANSI 3
  21. A CFESA-certified technician notices safety code violations on equipment while performing a routine service call. What is the appropriate professional response? Document the violations, inform the customer in writing, and recommend corrective action
  22. A steam kettle is producing insufficient steam pressure. After confirming adequate water supply, what is the next diagnostic step? Check and clean the steam generator scale buildup and inspect the safety valve
  23. What is the typical symptom of a failing motor capacitor in a commercial mixer? The mixer not starting or struggling to start
  24. Which standard establishes the energy efficiency requirements that commercial refrigerators must meet to qualify for the ENERGY STAR program? DOE 10 CFR Part 431
  25. A gas range burner produces a yellow, lifting flame instead of a blue cone flame. What is the most likely cause? Insufficient primary air or partially blocked air shutter
  26. A commercial dishwasher's wash arms are not rotating. The pump motor runs normally. What is the most likely cause? Clogged or blocked wash arm ports
  27. What condition is indicated when a compressor's suction line frosts heavily all the way back to the compressor? Overcharge of refrigerant or a flooding TXV
  28. Which of the following actions can help a technician become a candidate for managerial positions within a CFESA-certified business? Demonstrating strong leadership abilities and effective team management
  29. A commercial convection oven's gas valve fails to open when the thermostat calls for heat. After confirming 24V at the valve, the technician should: Replace the gas valve
  30. A commercial refrigeration system is short-cycling on the high-pressure cutout after a condenser coil cleaning. What is the most likely cause? Overcharge of refrigerant introduced during service
Turn these facts into recall: