CFESA Cheat Sheet 2026
The 30 highest-yield CFESA facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
100 questions
120 min time limit
70% to pass
- When using a clamp meter to diagnose a commercial cooking appliance, a technician measures amp draw significantly above nameplate rating. This indicates: → A possible short circuit, failed component drawing excess current, or mechanical binding
- What does the EPA's SNAP (Significant New Alternatives Policy) program regulate? → New refrigerants and substitutes for ozone-depleting substances
- Which tool is commonly used to measure electrical components in commercial food equipment? → Multimeter
- What is the correct manifold pressure for commercial LP (propane) gas equipment? → 11 inches W.C.
- How can CFESA-certified technicians improve operational efficiency during service calls? → By conducting thorough diagnostics and having common parts on hand
- When calibrating a commercial convection oven thermostat, a technician finds it reads 25°F high. The correct action is: → Adjust the calibration screw per manufacturer specification to correct the offset
- A technician measures a high head pressure and normal suction pressure in a walk-in cooler. The most likely cause is: → Dirty condenser coils
- When performing PM on a commercial tilting skillet (braising pan), a technician should lubricate the: → Tilt mechanism pivot points and gear assembly per manufacturer specifications
- What is the typical symptom of a failing motor capacitor in a commercial mixer? → The mixer not starting or struggling to start
- What condition is indicated when a compressor's suction line frosts heavily all the way back to the compressor? → Overcharge of refrigerant or a flooding TXV
- Which of the following actions can help a technician become a candidate for managerial positions within a CFESA-certified business? → Demonstrating strong leadership abilities and effective team management
- A commercial convection oven's gas valve fails to open when the thermostat calls for heat. After confirming 24V at the valve, the technician should: → Replace the gas valve
- A commercial range burner produces a yellow, lazy flame. The most likely cause is: → Insufficient primary air or gas pressure too high
- A technician is called to service a commercial steamship round that will not heat. The first step in the diagnostic process should be: → Verify power supply voltage and check the thermostat for continuity
- What does superheat indicate in a refrigeration system? → Temperature rise of vapor above its saturation point
- A technician notices oil pooling in the evaporator of a low-temperature display case. The most appropriate corrective action is: → Verify oil return lines and compressor crankcase heater operation
- Which safety device is designed to interrupt the electrical circuit in case of an overload or short circuit in commercial food equipment? → Circuit breaker
- During a refrigerant leak search on commercial equipment, which method is most effective for pinpointing small leaks in tight spaces? → Ultrasonic leak detector
- When replacing a faulty heating element in a commercial oven, what is a crucial step to ensure safety and proper function? → Ensuring the equipment is disconnected from the power source before installation
- A commercial convection oven heats unevenly — hot on one side and cool on the other. After confirming the fan operates, the technician should check: → Individual heating elements or burner sections for open circuits or uneven output
- What safety certification is required on commercial gas equipment sold in the United States? → CSA or ANSI Z83 certification
- What does the DOE's commercial refrigeration equipment efficiency standard require manufacturers to comply with? → Minimum energy efficiency levels expressed as daily energy consumption limits
- A commercial convection oven fan runs backward (opposite direction). The most likely cause is: → Two motor leads have been swapped, reversing the phase for a three-phase motor
- What is the correct method to test a commercial heating element for an open circuit? → Use a multimeter set to resistance (ohms) to measure element resistance with power off
- A commercial ice machine produces small, misshapen ice cubes. The most likely cause is: → Low water pressure or clogged water distribution tube
- What is the purpose of an atmospheric burner's primary air shutter on commercial gas cooking equipment? → Adjust the ratio of air mixed with gas before combustion
- In CFESA-certified businesses, what is the role of service contracts? → To guarantee regular income and ensure preventative maintenance
- What organization publishes the standards used to certify commercial food service equipment in the United States? → NSF International
- In a parallel rack refrigeration system used in supermarkets, which component controls refrigerant distribution to multiple display cases? → Electronic expansion valves and case controllers
- Subcooling in a refrigeration system refers to: → Cooling liquid refrigerant below its condensing temperature