Health and Safety Management Flashcards
7 cards from real CES practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 7 Health and Safety Management flashcards as text
Under OSHA's Hazard Communication Standard (HazCom 2012), Safety Data Sheets must contain how many sections?
Answer: 16
GHS-aligned SDSs are standardized into 16 sections covering identification, hazards, composition, first aid, fire-fighting, accidental release, handling/storage, exposure controls, physical/chemical properties, stability, toxicology, ecological info, disposal, transport, regulatory, and other information.
A confined space is classified as 'permit-required' under 29 CFR 1910.146 when it contains which characteristic?
Answer: A recognized serious safety or health hazard
A permit-required confined space has limited entry/exit, is not designed for continuous occupancy, AND contains or has the potential to contain a serious safety or health hazard.
The hierarchy of controls places which option as the MOST preferred method for managing workplace hazards?
Answer: Elimination
Elimination — physically removing the hazard — is the most effective control because it eliminates exposure entirely rather than managing it.
What is the OSHA permissible exposure limit (PEL) for noise as an 8-hour time-weighted average?
Answer: 90 dBA
OSHA's PEL for occupational noise exposure is 90 dBA as an 8-hour TWA, with a 5-dB exchange rate for shorter durations.
During a site inspection, you find containers of hazardous waste stored together that could react to form toxic gases. This situation violates which principle?
Answer: Compatibility grouping
RCRA and OSHA require incompatible wastes to be separated to prevent dangerous reactions; compatibility grouping ensures reactive, flammable, corrosive, and toxic materials are stored apart.
Under the OSHA Respiratory Protection Standard (29 CFR 1910.134), employees must be medically evaluated before fit-testing when using which type of respirator?
Answer: All respirators except disposable dust masks (N95 and tighter)
Medical evaluation is required before fit-testing and use of any tight-fitting respirator, including N95s and higher protection levels, to ensure the wearer can safely bear the physiological burden.
A Tier II report under EPCRA Section 312 must be submitted annually by March 1 when a facility stores hazardous chemicals above threshold quantities. Who receives these reports?
Answer: SERC, LEPC, and local fire department
Tier II reports go to the State Emergency Response Commission (SERC), Local Emergency Planning Committee (LEPC), and the local fire department to support emergency planning.