← All Certified Energy Auditor Certification Flashcard Decks

Motors, Drives, and Compressed Air Flashcards

7 cards from real Certified Energy Auditor Certification practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 7 Motors, Drives, and Compressed Air flashcards as text
  1. A compressed air dryer is rated at 500 scfm at 100°F inlet temperature. The actual inlet temperature is 120°F. What happens to the effective drying capacity?

    Answer: Capacity decreases because warmer air holds more moisture

    Higher inlet temperatures increase the moisture load on the dryer, reducing its effective capacity below the rated 500 scfm.

  2. What is meant by the term 'specific power' of a compressor as used in energy auditing?

    Answer: kW per 100 scfm of compressed air delivered

    Specific power (kW/100 scfm) is the standard metric for comparing compressor efficiency and system performance.

  3. Which of the following best describes the purpose of a receiver tank in a compressed air system?

    Answer: Provide capacitance to buffer demand swings and reduce compressor cycling

    Receiver tanks store compressed air to buffer short demand peaks and reduce compressor start/stop cycling, improving system stability.

  4. A 3-phase induction motor is operating with a measured power factor of 0.72. What is the most likely cause?

    Answer: Motor is operating at a fraction of its rated load

    Induction motors have poor power factor at light loads; power factor improves and peaks near full-load operation.

  5. When applying the affinity laws to a VFD-controlled pump or fan, which quantity does NOT scale with speed ratio?

    Answer: Rotational speed

    Rotational speed is the independent variable that drives the affinity law relationships — it is the input, not a derived scaled quantity.

  6. An auditor discovers a compressed air system using air at 90 psi for a blowoff application that only needs 15 psi. What is the recommended corrective measure?

    Answer: Install a point-of-use pressure regulator to reduce pressure at that application

    A point-of-use pressure regulator reduces pressure to the minimum required, avoiding energy waste from over-pressurizing low-pressure applications.

  7. For a premium efficiency (IE3) motor versus a standard efficiency motor of the same rating, which statement is generally true regarding motor operating temperature?

    Answer: IE3 motors run cooler because they have lower losses

    Premium efficiency motors have lower copper, iron, and stray losses, generating less heat and thus running at lower temperatures than standard motors.