  1. In Climate Zone 6 per ASHRAE 90.1, what is the primary reason exterior continuous insulation is placed outside the sheathing rather than inside the stud cavity?

    Answer: Exterior placement keeps the sheathing warm and above the dew point

    Placing continuous insulation on the exterior keeps the sheathing temperature above the dew point of interior air in cold climates, reducing condensation risk within the wall assembly.

  2. Which metric is used to evaluate the energy performance of skylights in commercial buildings under ASHRAE 90.1?

    Answer: U-factor and SHGC per the fenestration schedule

    ASHRAE 90.1 evaluates skylight performance through prescribed maximum U-factor and SHGC values based on climate zone, listed in fenestration tables.

  3. An auditor measures R-19 batt insulation compressed into a 3.5-inch cavity. What is the likely actual performance?

    Answer: R-13 or less — compression significantly reduces R-value

    Compressing fiberglass batt insulation significantly reduces its R-value; an R-19 batt compressed to a 3.5-inch space may perform at R-13 or below.

  4. Which type of window frame material has the highest thermal conductance (worst thermal performance)?

    Answer: Aluminum without a thermal break

    Aluminum is a highly conductive metal; without a thermal break (an insulating separator), aluminum frames conduct heat rapidly, resulting in poor thermal performance.

  5. What is the function of a drainage plane (weather-resistive barrier) behind cladding on an exterior wall?

    Answer: Secondary water control layer that drains bulk water away from the sheathing

    The drainage plane, such as housewrap or building paper, acts as a secondary water control layer that directs any bulk water that penetrates the cladding away from moisture-sensitive materials.

  6. During a duct pressurization test, a technician measures 15% duct leakage to outside. What is the primary energy impact of this finding?

    Answer: Conditioned air is lost directly to the exterior, increasing heating and cooling loads

    Duct leakage to outside means conditioned air is delivered to unconditioned space (attic, crawlspace) rather than living areas, directly wasting heating and cooling energy.

  7. Which building envelope detail is most critical for preventing ice dams on sloped roofs in cold climates?

    Answer: Installing continuous air and thermal barrier at the ceiling plane with adequate attic ventilation

    Ice dams form when heat escaping through the ceiling warms the roof deck and melts snow, which refreezes at the cold eaves; a continuous air and thermal barrier stops this heat loss.