Certified Energy Auditor Certification Cheat Sheet 2026
The 30 highest-yield Certified Energy Auditor Certification facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
100 questions
120 min time limit
70% to pass
- Which lighting metric measures the total luminous flux emitted per watt of electrical power consumed? → Luminous efficacy
- What does a savings-to-investment ratio (SIR) greater than 1.0 indicate about an energy project? → The project's discounted savings exceed its discounted costs
- What does a low superheat reading at the evaporator coil of a direct-expansion cooling system typically indicate? → The system is overcharged or the expansion valve is feeding too much refrigerant
- When evaluating a small wind turbine for a facility, what is the generally accepted minimum average annual wind speed for a viable installation? → 5 m/s (11.2 mph)
- What is the primary advantage of a variable air volume (VAV) system compared to a constant air volume (CAV) system in commercial buildings? → Reduced fan energy consumption at partial loads
- Which inverter technology is best suited for maximizing energy harvest when individual PV panels may experience partial shading? → Microinverter or DC power optimizer
- Which benchmarking tool is most commonly used by energy auditors in the US to compare a building's energy performance against similar facilities? → ENERGY STAR Portfolio Manager
- What is the primary limitation of using simple payback period as the sole criterion for evaluating energy conservation measures? → It ignores the time value of money and savings beyond the payback period
- Which energy conservation measure (ECM) typically offers the greatest ROI in a large industrial steam system? → Steam trap repair and replacement program
- Which thermal imaging condition is most likely to produce accurate results when scanning a building envelope for insulation defects? → When there is at least a 10°F temperature difference between indoors and outdoors
- What is the primary risk of performing air sealing work without addressing combustion safety in a home with atmospheric-vented appliances? → Backdrafting of combustion gases including carbon monoxide into the living space
- What is the recommended minimum outdoor air ventilation standard that energy auditors reference for commercial HVAC systems in the United States? → ASHRAE Standard 62.1
- Which control strategy is most effective for reducing energy consumption in a multi-zone HVAC system experiencing simultaneous heating and cooling? → Resetting supply air temperature based on zone demands
- What is the most common kind of loss in an AC motor at full load? → Resistive losses
- Which lighting control strategy is most effective for reducing energy use in a daylit open-plan office? → Continuous dimming with photosensor controls
- Which metric best indicates the seasonal cooling efficiency of a central air conditioning system? → SEER
- Which factor should an energy auditor prioritize when recommending a lighting retrofit for a warehouse with 24/7 operations? → Maximizing luminous efficacy and implementing high-bay occupancy sensors
- What is the recommended minimum R-value for attic insulation in US Climate Zone 5 according to IECC guidelines? → R-49
- What is the purpose of the ASHRAE Level II energy audit? → To provide detailed energy analysis with financial projections for recommended measures
- Which refrigerant management practice is required under EPA Section 608 for certified energy auditors to understand? → Recovery of refrigerants before disposing of equipment
- What is the recommended method for measuring the air infiltration rate of an existing commercial building during an energy audit? → Blower door depressurization test
- Which data collection method is most appropriate for identifying intermittent equipment operation issues during an energy audit? → Short-term monitoring with portable data loggers over a minimum two-week period
- A utility's electricity rate structure that differs according to the time of day is known as: → Time of use rate
- When performing duct leakage testing, what does the term 'duct leakage to outside' specifically refer to? → Air leaking from ducts into unconditioned spaces such as attics or crawlspaces
- What document does a CEA auditor typically produce to summarize recommended ECMs, projected savings, and implementation costs after an industrial energy audit? → Energy Audit Report with investment-grade analysis
- What is the internal rate of return (IRR) for an energy project? → The discount rate at which the net present value equals zero
- Which type of drive mechanism typically offers the highest efficiency for constant-speed motor applications? → Direct coupling
- What is the primary energy-saving opportunity identified when boiler blowdown heat recovery is implemented? → Recovering heat from blowdown water to preheat makeup water
- Which of the following is an example of a no-cost or low-cost energy conservation measure an auditor might recommend? → Adjusting thermostat setback schedules
- In a direct digital control (DDC) system, what is the function of the proportional-integral (PI) control loop for a cooling coil valve? → Modulates the valve position to maintain discharge air temperature at setpoint