โ† All CEAC Flashcard Decks

Building Codes & Regulatory Compliance Flashcards

7 cards from real CEAC practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Building Codes & Regulatory Compliance flashcards as text
  1. A building constructed in 1985 undergoes a 'change of occupancy' to a place of public accommodation. Under the ADA and IBC, which compliance standard applies?

    Answer: The path of travel to the altered area must be made accessible up to 20% of the construction cost

    A change of occupancy triggers the requirement to make the path of travel accessible up to a disproportionate-cost cap of 20% of the primary work cost.

  2. Which of the following correctly describes the 'technical infeasibility' exception under the 2010 ADA Standards for alterations?

    Answer: Compliance with accessibility requirements is structurally impractical given existing physical constraints

    Technical infeasibility means it is structurally or physically impractical to make an alteration comply with accessibility standards due to existing conditions.

  3. Under the ADA Standards, accessible toilet compartments that are side-transfer (standard) must have a minimum depth of how many inches?

    Answer: 59 inches

    Standard accessible toilet compartments (wall-hung water closet) require a minimum depth of 56 inches, but floor-mounted fixtures require 59 inches.

  4. The Architectural Barriers Act of 1968 applies to facilities that are:

    Answer: Designed, built, altered, or leased with federal funds or by federal agencies

    The ABA applies to facilities designed, constructed, altered, or leased with federal financial assistance or by federal agencies.

  5. In a multistory building without an elevator that is exempt from elevator requirements, which spaces must still be accessible on the non-accessible floor?

    Answer: Toilet rooms, drinking fountains, and public telephones on inaccessible floors

    Even in elevator-exempt buildings, toilet rooms, drinking fountains, and public telephones on inaccessible floors must meet accessibility standards.

  6. What is the minimum clear width required for a two-panel operable window in an accessible residential unit under the Fair Housing Act guidelines?

    Answer: 32 inches

    FHA guidelines require a minimum 32-inch clear opening width for operable windows in accessible units to allow access by persons using wheelchairs.

  7. Under the 2010 ADA Standards, what is the maximum cross slope permitted on an accessible parking surface?

    Answer: 1:48 (2%)

    Accessible parking spaces and access aisles must have a maximum slope of 1:48 (2%) in all directions to prevent wheelchairs from rolling.