โ† All CEA Flashcard Decks

Hazardous Materials Handling Flashcards

7 cards from real CEA practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Hazardous Materials Handling flashcards as text
  1. When conducting a hazardous materials audit at a facility storing Class 3 flammable liquids, which distance requirement must be verified between storage tanks and property lines?

    Answer: NFPA 30 setback requirements based on tank size and liquid flash point

    NFPA 30 (Flammable and Combustible Liquids Code) establishes setback distances from property lines, buildings, and public ways based on tank capacity and liquid classification.

  2. A facility subject to OSHA PSM stores more than the threshold quantity of anhydrous ammonia. Which element of the PSM standard requires a written plan for investigating process incidents and near-misses?

    Answer: Incident Investigation

    PSM's Incident Investigation element (29 CFR 1910.119(m)) requires a written investigation for incidents and near-misses within 48 hours of the event.

  3. Under 40 CFR Part 112, which facilities are required to prepare and implement a Spill Prevention, Control, and Countermeasure (SPCC) Plan?

    Answer: Non-transportation-related facilities with aggregate above-ground oil storage capacity greater than 1,320 gallons

    SPCC regulations apply to non-transportation facilities with aggregate above-ground storage capacity exceeding 1,320 gallons of oil in aboveground containers.

  4. During a hazardous waste audit, an inspector finds a container labeled only with the words 'old paint.' Under RCRA, this labeling is:

    Answer: A violation; containers must be labeled 'Hazardous Waste' with contents and accumulation start date

    RCRA requires hazardous waste containers to be labeled 'Hazardous Waste' and include the type of waste and the accumulation start date.

  5. Which internationally recognized system aligns GHS (Globally Harmonized System) chemical classification with US requirements through OSHA's HazCom 2012 standard?

    Answer: Safety Data Sheet (SDS) with 16-section format and GHS-aligned labels

    OSHA HazCom 2012 aligned US requirements with GHS by mandating the 16-section SDS format and standardized GHS label elements including pictograms, signal words, and hazard statements.

  6. A facility generates 0.8 kg of acute hazardous waste (P-listed) in a month. Under RCRA, this facility is regulated as a:

    Answer: Large Quantity Generator (LQG)

    Any facility generating 1 kg or more of acute (P-listed) hazardous waste per month is regulated as an LQG; 0.8 kg is just below that threshold and would be SQG if between 0 and 1 kg.

  7. An auditor reviews emergency response plans and finds the facility has not conducted an emergency response drill in over three years. Under EPCRA and RCRA combined requirements, drills are important because they:

    Answer: Verify that emergency coordinators and response procedures are functional and personnel are trained

    Emergency drills are required to ensure emergency coordinators, equipment, and procedures are tested and functional, satisfying RCRA contingency plan and EPCRA emergency planning requirements.