โ† All CCT Flashcard Decks

System Operation & Monitoring Flashcards

7 cards from real CCT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 System Operation & Monitoring flashcards as text
  1. A Casper system displays a 'heater fault' alarm during operation. What is the FIRST corrective action a technician should take?

    Answer: Acknowledge the alarm and check the heater current readings

    Acknowledging the alarm and checking heater current confirms whether the fault is a sensor issue or an actual heater failure before taking further action.

  2. When monitoring a Casper system, which parameter is the primary indicator of proper gas flow through the process chamber?

    Answer: Mass flow controller (MFC) actual vs. setpoint value

    The MFC actual flow vs. setpoint comparison directly indicates whether the correct amount of process gas is being delivered.

  3. During steady-state Casper operation, the process pressure suddenly rises above the setpoint. Which component failure is LEAST likely to cause this condition?

    Answer: Failed turbomolecular pump bearing

    A failed TMP bearing typically causes pump speed loss and reduced pumping capacity, but a bearing failure alone is less immediately likely to spike pressure compared to valve or sensor failures.

  4. A technician observes that the RF matching network is unable to reach a reflected power below 20 W during a Casper process run. What should be checked first?

    Answer: Chamber pressure and gas flow rates

    Abnormal chamber pressure or gas flow affects plasma impedance, which directly impacts the RF matching network's ability to minimize reflected power.

  5. In Casper system operation, what does a sustained rise in turbomolecular pump temperature indicate?

    Answer: Excessive process gas load or cooling system degradation

    Elevated TMP temperature beyond normal operating range suggests the pump is working harder than intended, often due to high gas load or inadequate cooling.

  6. Which Casper system log event would indicate a potential vacuum integrity issue rather than a process recipe problem?

    Answer: Repeated pump-down time exceeding baseline by >20%

    Pump-down time significantly exceeding the established baseline is a classic indicator of a leak or outgassing problem affecting vacuum integrity.

  7. A Casper system's end-point detection (EPD) signal fails to trigger at the expected process time. The technician should FIRST:

    Answer: Verify the EPD sensor signal and check for optical window contamination

    Contaminated optical windows are a common cause of EPD signal degradation and should be verified before replacing hardware or altering process parameters.