โ† All CCT Flashcard Decks

Safety Standards & Regulatory Compliance Flashcards

7 cards from real CCT practice questions. Tap to flip, then mark Knew It or Still Learning โ€” missed cards come back until you master them.

Read the first 7 Safety Standards & Regulatory Compliance flashcards as text
  1. A Casper technician completes a repair on a system containing more than 50 pounds of refrigerant. What record-keeping is required under EPA Section 608?

    Answer: Maintain service records documenting refrigerant added and recovered for at least 3 years

    EPA Section 608 requires technicians and owners to maintain service records for appliances containing 50+ pounds of refrigerant for a minimum of 3 years.

  2. What is the correct procedure when a technician finds that a recovery machine's oil has become contaminated with acid from a burned-out compressor?

    Answer: Change the oil, replace the filter-drier, and verify the machine is clean before the next use

    Contaminated recovery machine oil must be changed, the filter-drier replaced, and the unit verified clean to prevent cross-contaminating refrigerant from future jobs.

  3. Under OSHA's Hazard Communication Standard (29 CFR 1910.1200), what is an employer's obligation when introducing a new refrigerant chemical to the workplace?

    Answer: Obtain the SDS, update the chemical inventory, and train employees on the new hazard

    HazCom requires employers to maintain SDSs, update chemical inventories, and train all potentially exposed employees when new chemicals are introduced.

  4. Which type of fire extinguisher is appropriate for an electrical fire involving a refrigeration system's control panel?

    Answer: Class C (CO2 or dry chemical)

    Class C extinguishers are rated for energized electrical equipment and will not conduct electricity or damage components as water-based types would.

  5. What does the ASHRAE refrigerant safety classification 'A1' indicate?

    Answer: Lower toxicity and no flame propagation

    ASHRAE's 'A' designation means lower toxicity and '1' means no flame propagation was observed during testing.

  6. Which condition would require a technician to perform an immediate equipment shutdown and evacuation of an occupied space?

    Answer: Detection of refrigerant concentration above the ASHRAE 34 ATEL or room concentration limit

    When refrigerant concentration reaches or exceeds ASHRAE 34's Acute Toxicity Exposure Limit (ATEL) or room concentration limit, immediate evacuation is required to protect occupants.

  7. A technician must lift a heavy recovery cylinder onto a truck. Which safe lifting technique should be used to prevent injury?

    Answer: Bend at the knees, keep the back straight, and lift with the leg muscles

    Proper ergonomic lifting requires bending the knees, maintaining a straight back, and using leg muscles to reduce spinal injury risk.

Safety Standards & Regulatory Compliance Flashcards โ€” CCT Study Cards with Answers