  1. Under EPA Section 608, which refrigerants are exempt from the venting prohibition during small appliance repair?

    Answer: Natural refrigerants such as CO2 and propane

    EPA Section 608 exempts refrigerants that are not ozone-depleting substances and have negligible global warming potential, including natural refrigerants like CO2 and hydrocarbon refrigerants, from the venting prohibition.

  2. What is the purpose of a pressure relief valve on a refrigeration system per ASHRAE Standard 15?

    Answer: To prevent system pressure from exceeding safe limits and causing vessel rupture

    Pressure relief valves are safety devices that open to discharge refrigerant when system pressure threatens to exceed the design pressure of the vessel.

  3. A technician is using a recovery cylinder that is past its retest date. What should the technician do?

    Answer: Remove it from service and send it for retesting or dispose of it properly

    DOT regulations prohibit using cylinders past their retest date; they must be retested by a qualified facility or properly disposed of.

  4. Which safety data sheet (SDS) section contains information about proper personal protective equipment (PPE) for handling a refrigerant?

    Answer: Section 8 — Exposure Controls/Personal Protection

    SDS Section 8 specifically covers exposure limits, engineering controls, and required personal protective equipment.

  5. Under NFPA 70 (NEC), what is the required disconnect means for a hermetic refrigeration motor-compressor?

    Answer: A readily accessible disconnect within sight of or lockable in the open position from the equipment location

    NEC requires that the disconnect for motor-compressors be readily accessible and within sight of or capable of being locked open from the equipment location.

  6. Which safety hazard is associated with using an open flame or non-intrinsically safe equipment near flammable A2L refrigerants such as R-32?

    Answer: Risk of ignition since A2L refrigerants have lower flammability limits than A1 refrigerants

    A2L refrigerants are mildly flammable and can ignite under certain conditions, requiring ignition-source control and intrinsically safe tools.

  7. Which federal agency enforces regulations on the transportation of compressed gas cylinders containing refrigerants?

    Answer: Department of Transportation (DOT)

    DOT regulates the transportation of hazardous materials including compressed gas cylinders under 49 CFR.