← All CCT Flashcard Decks

CCT Electrical Systems & Wiring Flashcards

6 cards from real CCT practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.

Read the first 6 CCT Electrical Systems & Wiring flashcards as text
  1. In a Casper system using 24 V DC control wiring alongside 120 V AC power wiring, what is the NEC-required practice to prevent interference and hazards?

    Answer: Separate Class 2 (low-voltage) control wiring from power conductors in different raceways or maintain NEC-specified separation

    NEC Article 725 requires Class 2 low-voltage control conductors to be separated from power conductors to prevent induced voltages and shock hazards.

  2. A Casper system's circuit breaker trips repeatedly under normal load. Which condition most likely explains this behavior?

    Answer: The breaker is faulty, there is a partial ground fault, or the load exceeds the breaker rating

    Repeated tripping under normal load indicates either a defective breaker, a partial ground fault drawing extra current, or an actual load that exceeds the breaker's rating.

  3. What does a wiring diagram (schematic) used during Casper system installation primarily show?

    Answer: The electrical connections, component symbols, and circuit paths within the system

    A wiring schematic uses standardized symbols to show electrical connections and circuit paths, enabling technicians to trace circuits and verify correct wiring.

  4. Which wire termination method provides the most reliable, vibration-resistant connection in a Casper system subject to mechanical vibration?

    Answer: Crimped ring or fork terminal with the correct crimp tool

    Properly crimped ring or fork terminals create a gas-tight mechanical connection that resists loosening from vibration far better than other field-termination methods.

  5. Why is it important to verify polarity when connecting DC power to a Casper system control board?

    Answer: Connecting DC with reversed polarity can immediately damage or destroy polarity-sensitive components such as ICs, diodes, and capacitors

    Many DC components including ICs, electrolytic capacitors, and diodes are polarity-sensitive and will be instantly damaged or destroyed if connected with reversed DC polarity.

  6. What is the correct procedure after completing new wiring in a Casper system before restoring power for the first time?

    Answer: Perform a final visual inspection, verify all terminations are secure, confirm correct wire routing, and test insulation resistance before energizing

    Before first energization, a thorough pre-power checklist—visual inspection, torque check of terminations, insulation resistance test—prevents damage from wiring errors.