Building Codes & Standards Flashcards
7 cards from real CCI practice questions. Tap to flip, then mark Knew It or Still Learning โ missed cards come back until you master them.
Read the first 7 Building Codes & Standards flashcards as text
When a construction inspector encounters a code requirement that conflicts with the approved construction documents, the inspector should:
Answer: Notify the building official and document the discrepancy for resolution
The inspector must document the conflict and notify the building official, who has authority to determine the correct course of action.
According to ASCE 7, the Risk Category that applies to a hospital (essential facility) affects which design parameter?
Answer: The Importance Factor (I) used in wind, seismic, and snow load calculations
ASCE 7 assigns Risk Category IV to essential facilities like hospitals, which carries an Importance Factor greater than 1.0 for wind, seismic, and snow loads.
Under IBC Chapter 17, a 'Statement of Special Inspections' must be submitted to the building official by whom?
Answer: The registered design professional in responsible charge
IBC Section 1705.2 requires the registered design professional in responsible charge to prepare and submit the Statement of Special Inspections.
Which NFPA standard covers fire prevention in construction operations and is commonly referenced during active construction projects?
Answer: NFPA 241
NFPA 241, 'Standard for Safeguarding Construction, Alteration, and Demolition Operations,' addresses fire prevention practices during active construction.
Under the IBC, which condition would allow an existing building to use the 'alternative materials and methods' provision to deviate from a prescriptive code requirement?
Answer: The alternative is approved by the building official as providing equivalent performance
IBC Section 104.11 allows alternative materials and methods when the building official finds the proposed alternative provides at least equivalent performance to the prescriptive requirement.
A multi-story building uses high-strength bolts in structural steel connections. Which AWS or AISC standard governs the inspection of these bolted connections?
Answer: AISC 360 Chapter J and RCSC Specification for Structural Joints
AISC 360 Chapter J and the RCSC (Research Council on Structural Connections) Specification govern the design, installation, and inspection of high-strength bolted connections.
The IBC requires a 'change of occupancy' permit when:
Answer: The use of a building changes to a different occupancy classification
IBC Section 1001.1 and 1010 require a change of occupancy permit when the building's use changes to a different occupancy classification, triggering a new code compliance review.